EUVIMEDEUVIMED entdecken
Open Access

Measurement of ocular aberration in noise based on deep learning with a Shack-Hartmann wavefront sensor

Haobo Zhang, Yanrong Yang, Zitao Zhang, Chun Yin, Shengqian Wang, Kai Wei, Hao Chen, Junlei Zhao

Biomedical Optics Express · 01.11.2024 · 15 (11) · 6531

DOI: 10.1364/boe.541483 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 25.10.2024. Verfasst von Haobo Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: National Laboratory on Adaptive Optics, Chengdu 610209, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Scientific Instrument Developing Project of the Chinese Academy of Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Shack-Hartmann-based wavefront sensing combined with deep learning, due to its fast, accurate, and large dynamic range, has been widely studied in many fields including ocular aberration measurement. Problems such as noise and corneal reflection affect the accuracy of detection in practical measuring ocular aberration systems. This paper establishes a framework comprising of a noise-added model, Hartmannograms with corneal reflections and the corneal reflection elimination algorithm. Therefore, a more realistic data set is obtained, enabling the convolutional neural network to learn more comprehensive features and carry out real machine verification. The results show that the proposed method has excellent measurement accuracy. The root mean square error (RMSE) of the residual wavefront is 0.00924 ± 0.0207 λ (mean ± standard deviation) in simulation and 0.0496 ± 0.0156 λ in a real machine. Compared with other methods, this network combined with the proposed corneal reflection elimination algorithm is more accurate, speedier, and more widely applicable in the noise and corneal reflection situations, making it a promising tool for ocular aberration measurement.

Autor:innen und Institutionen

  • National Laboratory on Adaptive Optics, Chengdu 610209, China.
  • School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.
  • Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209, China.
  • University of Chinese Academy of Sciences, Beijing 100049, China.
  • Eye School, Chengdu University of TCM, Chengdu 610075, China.
  • Key Laboratory of Sichuan Province Ophthalmopathy Prevention & Cure and Visual Function Protection with TCM, Chengdu 610075, China.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Scientific Instrument Developing Project of the Chinese Academy of Sciences
  • Natural Science Foundation of Sichuan Province
  • Sichuan Province Science and Technology Support Program

Zitieren

APA

Zhang, H., Yang, Y., Zhang, Z., Yin, C., Wang, S., Wei, K., Chen, H., & Zhao, J. (2024). Measurement of ocular aberration in noise based on deep learning with a Shack-Hartmann wavefront sensor. Biomedical Optics Express, 15(11), 6531. https://doi.org/10.1364/boe.541483

Vancouver

Zhang H, Yang Y, Zhang Z, Yin C, Wang S, Wei K, et al. Measurement of ocular aberration in noise based on deep learning with a Shack-Hartmann wavefront sensor. Biomedical Optics Express. 2024;15(11):6531. doi:10.1364/boe.541483

BibTeX
@article{Zhang2024,
  author = {Zhang, Haobo and Yang, Yanrong and Zhang, Zitao and Yin, Chun and Wang, Shengqian and Wei, Kai and Chen, Hao and Zhao, Junlei},
  title = {Measurement of ocular aberration in noise based on deep learning with a Shack-Hartmann wavefront sensor},
  journal = {Biomedical Optics Express},
  year = {2024},
  volume = {15},
  number = {11},
  pages = {6531},
  doi = {10.1364/boe.541483}
}
Kostenlos starten →