Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 24.04.2024. Verfasst von Chengjin Song und 9 weiteren Autor:innen. Beteiligte Einrichtung: Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan…. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China, Guangdong Basic and Applied Basic Research Foundation, Guangdong Provincial Pearl River Talents Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microliter air-pulse optical coherence elastography (OCE) has recently been proposed for the characterization of soft-tissue biomechanics using transient, sub-nanometer to micrometer-scale natural frequency oscillations. However, previous studies have not been able to provide real-time air-pulse monitoring during OCE natural frequency measurement, which could lead to inaccurate measurement results due to the unknown excitation spectrum. To address this issue, we introduce a dual-channel air-pulse OCE method, with one channel stimulating the sample and the other being simultaneously measured with a pressure sensor. This allows for more accurate natural frequency characterization using the frequency response function, as proven by a comprehensive comparison under different conditions with a diverse range of excitation spectra (from broad to narrow, clean to noisy) as well as a diverse set of sample response spectra. We also demonstrate the capability of the frequency-response analysis in distinguishing samples with different stiffness levels: the dominant natural frequencies increased with agar concentrations (181–359 Hz, concentrations: 1–2%, and maximum displacements: 0.12–0.47 µm) and intraocular pressures (IOPs) for the silicone cornea (333–412 Hz, IOP: 5–40 mmHg, and maximum displacements: 0.41–0.52 µm) under a 200 Pa stimulation pressure. These frequencies remained consistent across different air-pulse durations (3 ms to 35 ms). The dual-channel OCE approach that uses transient, low-pressure stimulation and high-resolution imaging holds the potential to advance our understanding of sample frequency responses, especially when investigating delicate tissues such as the human cornea in vivo .

Autor:innen und Institutionen

  • Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China.
  • Institute of Engineering and Technology, Hubei University of Science and Technology, Xianning, Hubei 437100, China.
  • College of Optometry, University of Houston, Houston, TX 77204, USA.
  • Guangdong Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China.
  • Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Peking University, Beijing 100142, China.
  • Biomedical Engineering Department, Peking University, Beijing 100081, China.

ORCID-Profile: Michael D Twa, Jingjiang Xu, Gongpu Lan

Förderung

  • National Natural Science Foundation of China
  • Guangdong Basic and Applied Basic Research Foundation
  • Guangdong Provincial Pearl River Talents Program
  • Guangdong Eye Intelligent Medical Imaging Equipment Engineering Technology Research Center
  • Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory
  • National Eye Institute

Zitieren

APA

Song, C., He, W., Feng, J., Twa, M. D., Huang, Y., Xu, J., Qin, J., An, L., Wei, X., & Lan, G. (2024). Dual-channel air-pulse optical coherence elastography for frequency-response analysis. Biomedical Optics Express, 15(5), 3301. https://doi.org/10.1364/boe.520551

Vancouver

Song C, He W, Feng J, Twa MD, Huang Y, Xu J, et al. Dual-channel air-pulse optical coherence elastography for frequency-response analysis. Biomedical Optics Express. 2024;15(5):3301. doi:10.1364/boe.520551

BibTeX
@article{Song2024,
  author = {Song, Chengjin and He, Weichao and Feng, Jinping and Twa, Michael D and Huang, Yanping and Xu, Jingjiang and Qin, Jia and An, Lin and Wei, Xunbin and Lan, Gongpu},
  title = {Dual-channel air-pulse optical coherence elastography for frequency-response analysis},
  journal = {Biomedical Optics Express},
  year = {2024},
  volume = {15},
  number = {5},
  pages = {3301},
  doi = {10.1364/boe.520551}
}
Kostenlos starten →