EUVIMEDEUVIMED entdecken
Open Access

Quantifying image quality in AOSLO images of photoreceptors

Brea D Brennan, Heather Heitkotter iD, Joseph Carroll iD, Sergey Tarima, Robert F Cooper iD

Biomedical Optics Express · 01.05.2024 · 15 (5) · 2849

DOI: 10.1364/boe.516477 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 04.04.2024. Verfasst von Brea D Brennan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Joint Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, Wisconsin, USA. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NEI NIH HHS, NCATS NIH HHS, NCRR NIH HHS.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of “quality” to describe the usefulness of an image is ubiquitous but is often subject to domain specific constraints. Despite its continued use as an imaging modality, adaptive optics scanning light ophthalmoscopy (AOSLO) lacks a dedicated metric for quantifying the quality of an image of photoreceptors. Here, we present an approach to evaluating image quality that extracts an estimate of the signal to noise ratio. We evaluated its performance in 528 images of photoreceptors from two AOSLOs, two modalities, and healthy or diseased retinas. The algorithm was compared to expert graders’ ratings of the images and previously published image quality metrics. We found no significant difference in the SNR and grades across all conditions. The SNR and the grades of the images were moderately correlated. Overall, this algorithm provides an objective measure of image quality that closely relates to expert assessments of quality in both confocal and split-detector AOSLO images of photoreceptors.

Autor:innen und Institutionen

  • Joint Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • Department of Cell Biology, Neurobiology & Anatomy, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • Department of Ophthalmology and Visual Science, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • Division of Biostatistics, Institute for Health and Equity, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.

ORCID-Profile: Heather Heitkotter, Joseph Carroll, Robert F Cooper

Förderung

  • NEI NIH HHS
  • NCATS NIH HHS
  • NCRR NIH HHS
  • Foundation Fighting Blindness
  • National Eye Institute
  • National Institutes of Health

Zitieren

APA

Brennan, B. D., Heitkotter, H., Carroll, J., Tarima, S., & Cooper, R. F. (2024). Quantifying image quality in AOSLO images of photoreceptors. Biomedical Optics Express, 15(5), 2849. https://doi.org/10.1364/boe.516477

Vancouver

Brennan BD, Heitkotter H, Carroll J, Tarima S, Cooper RF. Quantifying image quality in AOSLO images of photoreceptors. Biomedical Optics Express. 2024;15(5):2849. doi:10.1364/boe.516477

BibTeX
@article{Brennan2024,
  author = {Brennan, Brea D and Heitkotter, Heather and Carroll, Joseph and Tarima, Sergey and Cooper, Robert F},
  title = {Quantifying image quality in AOSLO images of photoreceptors},
  journal = {Biomedical Optics Express},
  year = {2024},
  volume = {15},
  number = {5},
  pages = {2849},
  doi = {10.1364/boe.516477}
}