EUVIMEDEUVIMED entdecken
Open Access

Optical diffraction tomography for assessing single cell models in angular light scattering

Kaitlin J Dunn iD, Alex Matlock iD, George Funkenbusch, Zahid Yaqoob iD, Peter T C So, Andrew J Berger iD

Biomedical Optics Express · 01.02.2024 · 15 (2) · 973

DOI: 10.1364/boe.512149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 24.01.2024. Verfasst von Kaitlin J Dunn und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Institute of Optics, University of Rochester, Rochester, NY, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIDA NIH HHS, NHLBI NIH HHS.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Angularly resolved light scattering (ALS) has become a useful tool for assessing the size and refractive index of biological scatterers at cellular and organelle length scales. Sizing organelle populations with ALS relies on Mie scattering theory models, which require significant assumptions about the object, including spherical scatterers and a homogeneous medium. These assumptions may incur greater error at the single cell level, where there are fewer scatterers to be averaged over. We investigate the validity of these assumptions using 3D refractive index (RI) tomograms measured via optical diffraction tomography (ODT). We compute the angular scattering on digitally manipulated tomograms with increasingly strong model assumptions, including RI-matched immersion media, homogeneous cytosol, and spherical organelles. We also compare the tomogram-computed angular scattering to experimental measurements of angular scattering from the same cells to ensure that the ODT-based approach accurately models angular scattering. We show that enforced RI-matching with the immersion medium and a homogeneous cytosol significantly affects the angular scattering intensity shape, suggesting that these assumptions can reduce the accuracy of size distribution estimates.

Autor:innen und Institutionen

  • The Institute of Optics, University of Rochester, Rochester, NY, USA.
  • Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
  • Department of Biomedical Engineering, Duke University, Durham, NC, USA.
  • Department of Biomedical Engineering, Boston University, Boston, MA, USA.
  • Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.

ORCID-Profile: Kaitlin J Dunn, Alex Matlock, Zahid Yaqoob, Andrew J Berger

Förderung

  • NIBIB NIH HHS
  • NIDA NIH HHS
  • NHLBI NIH HHS
  • NIGMS NIH HHS
  • National Institutes of Health
  • Hamamatsu Corporation
  • The MIT Laser Biomedical Research Center

Zitieren

APA

Dunn, K. J., Matlock, A., Funkenbusch, G., Yaqoob, Z., So, P. T. C., & Berger, A. J. (2024). Optical diffraction tomography for assessing single cell models in angular light scattering. Biomedical Optics Express, 15(2), 973. https://doi.org/10.1364/boe.512149

Vancouver

Dunn KJ, Matlock A, Funkenbusch G, Yaqoob Z, So PTC, Berger AJ. Optical diffraction tomography for assessing single cell models in angular light scattering. Biomedical Optics Express. 2024;15(2):973. doi:10.1364/boe.512149

BibTeX
@article{Dunn2024,
  author = {Dunn, Kaitlin J and Matlock, Alex and Funkenbusch, George and Yaqoob, Zahid and So, Peter T C and Berger, Andrew J},
  title = {Optical diffraction tomography for assessing single cell models in angular light scattering},
  journal = {Biomedical Optics Express},
  year = {2024},
  volume = {15},
  number = {2},
  pages = {973},
  doi = {10.1364/boe.512149}
}
Kostenlos starten →