EUVIMEDEUVIMED entdecken
Open Access

Lung cancer cells detection by a photoelectrochemical MoS 2 biosensing chip

Chun-Liang Lai, Riya Karmakar, Arvind Mukundan iD, Wei-Chung Chen, I-Chen Wu, Vladimir E Fedorov, Shih-Wei Feng, Ubol Choomjinda, Shu-Fang Huang, Hsiang-Chen Wang iD

Biomedical Optics Express · 01.02.2024 · 15 (2) · 753

DOI: 10.1364/boe.511900 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 16.01.2024. Verfasst von Chun-Liang Lai und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonology and Critical Care, Department of Internal Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, No. 2, Minsh…. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Kaohsiung Armed Forces General Hospital, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation-National Chung Cheng University Joint Research Program, National Science and Technology Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research aims to explore the potential application of this approach in the production of biosensor chips. The biosensor chip is utilized for the identification and examination of early-stage lung cancer cells. The findings of the optical microscope were corroborated by the field emission scanning electron microscopy, which provided further evidence that the growth of MoS 2 is uniform and that there is minimal disruption in the electrode, hence minimizing the likelihood of an open circuit creation. Furthermore, the bilayer structure of the produced MoS 2 has been validated through the utilization of Raman spectroscopy. A research investigation was undertaken to measure the photoelectric current generated by three various types of clinical samples containing lung cancer cells, specifically the CL1, NCI-H460, and NCI-H520 cell lines. The findings from the empirical analysis indicate that the coefficient of determination (R-Square) for the linear regression model was approximately 98%. Furthermore, the integration of a double-layer MoS 2 film resulted in a significant improvement of 38% in the photocurrent, as observed in the device's performance.

Autor:innen und Institutionen

  • Division of Pulmonology and Critical Care, Department of Internal Medicine, Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, No. 2, Minsheng Road, Dalin, Chiayi 62247, Taiwan.
  • School of Medicine, Tzu Chi University, 701 Zhongyang Rd., Sec. 3, Hualien 97004, Taiwan.
  • Department of Mechanical Engineering and Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Road, Min Hsiung, Chiayi City 62102, Taiwan.
  • Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan.
  • Department of Medicine and Graduate Institute of Clinical Medicine, College of Medicine, Kaohsiung Medical University, No. 100, Tzyou 1st Rd., Sanmin Dist., Kaohsiung City 80756, Taiwan.
  • Nikolaev Institute of Inorganic Chemistry, Siberian Branch of Russian Academy of Sciences, Novosibirsk 630090, Russia.

ORCID-Profile: Arvind Mukundan, Hsiang-Chen Wang

Förderung

  • Kaohsiung Armed Forces General Hospital
  • Dalin Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation-National Chung Cheng University Joint Research Program
  • National Science and Technology Council

Zitieren

APA

Lai, C. L., Karmakar, R., Mukundan, A., Chen, W. C., Wu, I. C., Fedorov, V. E., Feng, S. W., Choomjinda, U., Huang, S. F., & Wang, H. C. (2024). Lung cancer cells detection by a photoelectrochemical MoS 2 biosensing chip. Biomedical Optics Express, 15(2), 753. https://doi.org/10.1364/boe.511900

Vancouver

Lai CL, Karmakar R, Mukundan A, Chen WC, Wu IC, Fedorov VE, et al. Lung cancer cells detection by a photoelectrochemical MoS 2 biosensing chip. Biomedical Optics Express. 2024;15(2):753. doi:10.1364/boe.511900

BibTeX
@article{Lai2024,
  author = {Lai, Chun-Liang and Karmakar, Riya and Mukundan, Arvind and Chen, Wei-Chung and Wu, I-Chen and Fedorov, Vladimir E and Feng, Shih-Wei and Choomjinda, Ubol and Huang, Shu-Fang and Wang, Hsiang-Chen},
  title = {Lung cancer cells detection by a photoelectrochemical MoS 2 biosensing chip},
  journal = {Biomedical Optics Express},
  year = {2024},
  volume = {15},
  number = {2},
  pages = {753},
  doi = {10.1364/boe.511900}
}
Kostenlos starten →