Miniature line-scanned dual-axis confocal microscope for versatile clinical use
Biomedical Optics Express · 01.11.2023 · 14 (11) · 6048
DOI: 10.1364/boe.503478 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 31.10.2023. Verfasst von Kevin W Bishop und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Washington, Seattle, WA 98195, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Science Foundation, National Cancer Institute.
Abstract (Originalsprache)
A miniature optical-sectioning fluorescence microscope with high sensitivity and resolution would enable non-invasive and real-time tissue inspection, with potential use cases including early disease detection and intraoperative guidance. Previously, we developed a miniature MEMS-based dual-axis confocal (DAC) microscope that enabled video-rate optically sectioned in vivo microscopy of human tissues. However, the device’s clinical utility was limited due to a small field of view, a non-adjustable working distance, and a lack of a sterilization strategy. In our latest design, we have made improvements to achieve a 2x increase in the field of view (600 × 300 µm) and an adjustable working distance range of 150 µm over a wide range of excitation/emission wavelengths (488–750 nm), all while maintaining a high frame rate of 15 frames per second (fps). Furthermore, the device is designed to image through a disposable sterile plastic drape for convenient clinical use. We rigorously characterize the performance of the device and show example images of ex vivo tissues to demonstrate the optical performance of our new design, including fixed mouse skin and human prostate, as well as fresh mouse kidney, mouse intestine, and human head and neck surgical specimens with corresponding H&E histology. These improvements will facilitate clinical testing and translation.
Autor:innen und Institutionen
- Department of Bioengineering, University of Washington, Seattle, WA 98195, USA.
- Department of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA.
- Department of Biology, University of Washington, Seattle, Washington 98195, USA.
- Ivy Brain Tumor Center, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix 85013, AZ, USA.
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix 85013, AZ, USA.
- Department of Laboratory Medicine & Pathology, University of Washington, Seattle, WA 98195, USA.
ORCID-Profile: Kevin W Bishop, Sarah S L Chow, Jonathan T C Liu
Förderung
- NCI NIH HHS
- National Science Foundation
- National Cancer Institute
Zitieren
APA
Bishop, K. W., Hu, B., Vyawhare, R., Yang, Z., Liang, D. C., Gao, G., Baraznenok, E., Han, Q., Lan, L., Chow, S. S. L., Sanai, N., & Liu, J. T. C. (2023). Miniature line-scanned dual-axis confocal microscope for versatile clinical use. Biomedical Optics Express, 14(11), 6048. https://doi.org/10.1364/boe.503478
Vancouver
Bishop KW, Hu B, Vyawhare R, Yang Z, Liang DC, Gao G, et al. Miniature line-scanned dual-axis confocal microscope for versatile clinical use. Biomedical Optics Express. 2023;14(11):6048. doi:10.1364/boe.503478
BibTeX
@article{Bishop2023,
author = {Bishop, Kevin W and Hu, Bingwen and Vyawhare, Rajat and Yang, Zelin and Liang, David C and Gao, Gan and Baraznenok, Elena and Han, Qinghua and Lan, Lydia and Chow, Sarah S L and Sanai, Nader and Liu, Jonathan T C},
title = {Miniature line-scanned dual-axis confocal microscope for versatile clinical use},
journal = {Biomedical Optics Express},
year = {2023},
volume = {14},
number = {11},
pages = {6048},
doi = {10.1364/boe.503478}
}