EUVIMEDEUVIMED entdecken
Open Access

Miniature line-scanned dual-axis confocal microscope for versatile clinical use

Kevin W Bishop iD, Bingwen Hu, Rajat Vyawhare, Zelin Yang, David C Liang, Gan Gao, Elena Baraznenok, Qinghua Han, Lydia Lan, Sarah S L Chow iD, Nader Sanai, Jonathan T C Liu iD

Biomedical Optics Express · 01.11.2023 · 14 (11) · 6048

DOI: 10.1364/boe.503478 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 31.10.2023. Verfasst von Kevin W Bishop und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Washington, Seattle, WA 98195, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Science Foundation, National Cancer Institute.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A miniature optical-sectioning fluorescence microscope with high sensitivity and resolution would enable non-invasive and real-time tissue inspection, with potential use cases including early disease detection and intraoperative guidance. Previously, we developed a miniature MEMS-based dual-axis confocal (DAC) microscope that enabled video-rate optically sectioned in vivo microscopy of human tissues. However, the device’s clinical utility was limited due to a small field of view, a non-adjustable working distance, and a lack of a sterilization strategy. In our latest design, we have made improvements to achieve a 2x increase in the field of view (600 × 300 µm) and an adjustable working distance range of 150 µm over a wide range of excitation/emission wavelengths (488–750 nm), all while maintaining a high frame rate of 15 frames per second (fps). Furthermore, the device is designed to image through a disposable sterile plastic drape for convenient clinical use. We rigorously characterize the performance of the device and show example images of ex vivo tissues to demonstrate the optical performance of our new design, including fixed mouse skin and human prostate, as well as fresh mouse kidney, mouse intestine, and human head and neck surgical specimens with corresponding H&E histology. These improvements will facilitate clinical testing and translation.

Autor:innen und Institutionen

  • Department of Bioengineering, University of Washington, Seattle, WA 98195, USA.
  • Department of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA.
  • Department of Biology, University of Washington, Seattle, Washington 98195, USA.
  • Ivy Brain Tumor Center, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix 85013, AZ, USA.
  • Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix 85013, AZ, USA.
  • Department of Laboratory Medicine & Pathology, University of Washington, Seattle, WA 98195, USA.

ORCID-Profile: Kevin W Bishop, Sarah S L Chow, Jonathan T C Liu

Förderung

  • NCI NIH HHS
  • National Science Foundation
  • National Cancer Institute

Zitieren

APA

Bishop, K. W., Hu, B., Vyawhare, R., Yang, Z., Liang, D. C., Gao, G., Baraznenok, E., Han, Q., Lan, L., Chow, S. S. L., Sanai, N., & Liu, J. T. C. (2023). Miniature line-scanned dual-axis confocal microscope for versatile clinical use. Biomedical Optics Express, 14(11), 6048. https://doi.org/10.1364/boe.503478

Vancouver

Bishop KW, Hu B, Vyawhare R, Yang Z, Liang DC, Gao G, et al. Miniature line-scanned dual-axis confocal microscope for versatile clinical use. Biomedical Optics Express. 2023;14(11):6048. doi:10.1364/boe.503478

BibTeX
@article{Bishop2023,
  author = {Bishop, Kevin W and Hu, Bingwen and Vyawhare, Rajat and Yang, Zelin and Liang, David C and Gao, Gan and Baraznenok, Elena and Han, Qinghua and Lan, Lydia and Chow, Sarah S L and Sanai, Nader and Liu, Jonathan T C},
  title = {Miniature line-scanned dual-axis confocal microscope for versatile clinical use},
  journal = {Biomedical Optics Express},
  year = {2023},
  volume = {14},
  number = {11},
  pages = {6048},
  doi = {10.1364/boe.503478}
}
Kostenlos starten →