EUVIMEDEUVIMED entdecken
Open Access

Method to determine the centration of a lenticule of tissue extracted from a cornea

Hamed Haidari, Victor Derhartunian, Samuel Arba-Mosquera iD

Biomedical Optics Express · 01.08.2023 · 14 (8) · 4080

DOI: 10.1364/boe.495416 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 11.07.2023. Verfasst von Hamed Haidari und 2 weiteren Autor:innen. Beteiligte Einrichtung: Technische Hochschule Aschaffenburg University of Applied Sciences (student), Aschaffenburg, D- 63743, Germany. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple and novel method to analyse the centration of a lenticule of tissue extracted from a cornea has been developed, in which the centre of “mass” of the individual differences between post and preoperative maps of several corneal metrics represents the lenticule centration and its spatial distance to a reference point (aimed centration) determines the decentration. Different parameters have been evaluated to weight the centre of “mass”. The robustness of the methods has been evaluated using perturbation analysis (adding white-noise to the data) based on realistic uncertainties. A clipped analysis has been performed to prevent large, localised areas of lacking/missing data from affecting the centre of “mass”. The method has been tested on a pilot cohort of clinical data showing 30% and 63% of the treatments within 200 µm of decentration for corneal thickness and refractive equivalent power, respectively. Except for anterior elevation with a total standard deviation of 17 µm, all other metrics show excellent precision of ∼5 µm. The method provides a reliable and objective way to determine the centration of a lenticule of tissue extracted from a cornea and it can be applied to any topo- or tomographic derived metric.

Autor:innen und Institutionen

  • Technische Hochschule Aschaffenburg University of Applied Sciences (student), Aschaffenburg, D- 63743, Germany.
  • SCHWIND eye-tech-solutions, Kleinostheim, D- 63801, Germany.
  • EYELASER WIEN, Wien, D- 1010, Austria.

ORCID-Profile: Samuel Arba-Mosquera

Zitieren

APA

Haidari, H., Derhartunian, V., & Arba-Mosquera, S. (2023). Method to determine the centration of a lenticule of tissue extracted from a cornea. Biomedical Optics Express, 14(8), 4080. https://doi.org/10.1364/boe.495416

Vancouver

Haidari H, Derhartunian V, Arba-Mosquera S. Method to determine the centration of a lenticule of tissue extracted from a cornea. Biomedical Optics Express. 2023;14(8):4080. doi:10.1364/boe.495416

BibTeX
@article{Haidari2023,
  author = {Haidari, Hamed and Derhartunian, Victor and Arba-Mosquera, Samuel},
  title = {Method to determine the centration of a lenticule of tissue extracted from a cornea},
  journal = {Biomedical Optics Express},
  year = {2023},
  volume = {14},
  number = {8},
  pages = {4080},
  doi = {10.1364/boe.495416}
}
Kostenlos starten →