Improving probe-beam stability in spherical-cell atomic magnetometers using 4 f spatial filtering
Applied Optics · 10.11.2026 · 65 (32) · 11447
DOI: 10.1364/ao.615991 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Optics, online erschienen am 04.11.2026. Verfasst von XueJing Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: The Key Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, School of Optical-Electrical and Computer Engineering, U…. Die Arbeit nennt 20 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Spherical vapor cells introduce position-dependent refraction and variations in the incident-angle distribution that can destabilize the probe-beam polarization readout in atomic magnetometers. We propose a pre-positioned, 4 f spatial-filtering system to suppress high-angle components of the probe beam and improve its stability against relative position disturbances between the beam and the vapor cell. A Jones-matrix model is developed to describe the effect of incident-angle variations on polarization, and experiments are performed to evaluate the extinction ratio and signal-to-noise ratio ( SNR ). With 4 f filtering, the extinction-ratio variation is reduced by 15.67%–65.39%, while the SNR variation decreases by 19.21%–74.54% under vapor-cell position perturbations. Zemax simulations further confirm improved received-intensity stability.
Autor:innen und Institutionen
- The Key Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, Chi…
- The School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
ORCID-Profile: ZhenXiang Tang
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Liu, X., Tang, Z., & Li, Y. (2026). Improving probe-beam stability in spherical-cell atomic magnetometers using 4 f spatial filtering. Applied Optics, 65(32), 11447. https://doi.org/10.1364/ao.615991
Vancouver
Liu X, Tang Z, Li Y. Improving probe-beam stability in spherical-cell atomic magnetometers using 4 f spatial filtering. Applied Optics. 2026;65(32):11447. doi:10.1364/ao.615991
BibTeX
@article{Liu2026,
author = {Liu, XueJing and Tang, ZhenXiang and Li, Yang},
title = {Improving probe-beam stability in spherical-cell atomic magnetometers using 4 f spatial filtering},
journal = {Applied Optics},
year = {2026},
volume = {65},
number = {32},
pages = {11447},
doi = {10.1364/ao.615991}
}
EUVIMED