EUVIMEDEUVIMED entdecken
Crossref

Three-dimensional residual projection completion for coded-aperture cone-beam computed tomography

Tianyi Mao iD, Yushen Jiang, Leijun Zheng, Xu Ma iD, Shujin Zhu, Xiubin Dai

Applied Optics · 10.11.2026 · 65 (32) · 11502

DOI: 10.1364/ao.613760 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 05.11.2026. Verfasst von Tianyi Mao und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Automation, Nanjing University of Posts and Telecommunications, Nanjing 210023, China. Die Arbeit nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jiangsu Provincial Key Research and Development Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Coded aperture cone-beam computed tomography reduces X-ray exposure by blocking a subset of detector-view rays, but the resulting interleaved missing samples make direct volumetric reconstruction computationally demanding and prone to artifacts. This paper presents a projection-domain reconstruction framework in which a 3D U-Net learns residual corrections to complete the coded projection tensor before Feldkamp–Davis–Kress reconstruction. The network takes the measured coded projection, an interpolation-based base estimate, and the binary aperture mask as input, and it predicts a bounded residual correction only for unmeasured samples while preserving measured data exactly. A training objective combining missing-region fidelity, seam intensity consistency, and seam gradient consistency is used to suppress discontinuities around coded-aperture boundaries. Experiments on 188 projection volumes show that the selected loss composition improves projection completion and yields reconstruction results close to the reference FDK images. Over 38 testing cases, the mean Ref-vs-Pred reconstruction PSNR is 44.6 dB and the mean SSIM value is 0.98.

Autor:innen und Institutionen

  • College of Automation, Nanjing University of Posts and Telecommunications, Nanjing 210023, China.
  • Key Laboratory of Photoelectronic Imaging Technology and System of Ministry of Education of China, School of Optics and Photonics,Beijing Institute of Technology, Beijing 100081, China.

ORCID-Profile: Tianyi Mao, Xu Ma

Förderung

  • National Natural Science Foundation of China
  • Jiangsu Provincial Key Research and Development Program

Zitieren

APA

Mao, T., Jiang, Y., Zheng, L., Ma, X., Zhu, S., & Dai, X. (2026). Three-dimensional residual projection completion for coded-aperture cone-beam computed tomography. Applied Optics, 65(32), 11502. https://doi.org/10.1364/ao.613760

Vancouver

Mao T, Jiang Y, Zheng L, Ma X, Zhu S, Dai X. Three-dimensional residual projection completion for coded-aperture cone-beam computed tomography. Applied Optics. 2026;65(32):11502. doi:10.1364/ao.613760

BibTeX
@article{Mao2026,
  author = {Mao, Tianyi and Jiang, Yushen and Zheng, Leijun and Ma, Xu and Zhu, Shujin and Dai, Xiubin},
  title = {Three-dimensional residual projection completion for coded-aperture cone-beam computed tomography},
  journal = {Applied Optics},
  year = {2026},
  volume = {65},
  number = {32},
  pages = {11502},
  doi = {10.1364/ao.613760}
}
Kostenlos starten →