Time-optimized frame-filtered ghost imaging with pseudo-thermal light and a SPAD array
Applied Optics · 10.11.2026 · 65 (32) · 11469
DOI: 10.1364/ao.612408 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Optics, online erschienen am 05.11.2026. Verfasst von V S Starovoitov und 5 weiteren Autor:innen. Beteiligte Einrichtung: B.I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Nezavisimosti Ave. 68, Minsk 220072, Belarus. Die Arbeit nennt 45 Literaturangaben.
Abstract (Originalsprache)
Ghost imaging experiments with a single SPAD array exploited simultaneously as a several-pixel “bucket” detector and an imaging camera are performed. The experiments use a pseudo-thermal light source under conditions where the light intensity is so low that the dark SPAD counts have a noticeable destructive effect on the imaging. To minimize the influence of dark counts on the ghost image and reduce the fluctuations in the random speckle structure of the image, the acquired data are filtered by the number of counts per frame, and the ghost images are smoothed using a moving short-range averaging. Proper filter tuning leads to a significant reduction in the data-acquisition time required to obtain good-quality ghost images.
Autor:innen und Institutionen
- B.I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Nezavisimosti Ave. 68, Minsk 220072, Belarus.
- Fondazione Bruno Kessler FBK, Trento 38122, Italy.
- Current address: Sony Semiconductor Solutions Europe, Trento, Italy.
ORCID-Profile: V N Chizhevsky, D Mogilevtsev, M Perenzoni, L Gasparini
Zitieren
APA
Starovoitov, V. S., Samoilenko, N. D., Chizhevsky, V. N., Mogilevtsev, D., Perenzoni, M., & Gasparini, L. (2026). Time-optimized frame-filtered ghost imaging with pseudo-thermal light and a SPAD array. Applied Optics, 65(32), 11469. https://doi.org/10.1364/ao.612408
Vancouver
Starovoitov VS, Samoilenko ND, Chizhevsky VN, Mogilevtsev D, Perenzoni M, Gasparini L. Time-optimized frame-filtered ghost imaging with pseudo-thermal light and a SPAD array. Applied Optics. 2026;65(32):11469. doi:10.1364/ao.612408
BibTeX
@article{Starovoitov2026,
author = {Starovoitov, V S and Samoilenko, N D and Chizhevsky, V N and Mogilevtsev, D and Perenzoni, M and Gasparini, L},
title = {Time-optimized frame-filtered ghost imaging with pseudo-thermal light and a SPAD array},
journal = {Applied Optics},
year = {2026},
volume = {65},
number = {32},
pages = {11469},
doi = {10.1364/ao.612408}
}