High-efficiency, non-iterative phase and amplitude calibration method for integrated optical phased arrays
Applied Optics · 20.08.2026 · 65 (24) · 8432
DOI: 10.1364/ao.609254 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Optics, online erschienen am 17.08.2026. Verfasst von Lin Zhang und 7 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Department of Science and Technology of Hunan Province, National University of Defense Technology.
Abstract (Originalsprache)
Integrated optical phased arrays (OPAs), owing to their high integration level and wide-angle beam steering capability, are key promising components for 3D/4D sensing. However, phase and amplitude errors can significantly degrade their signal quality. Traditional integrated OPA calibration methods, which rely on iterative optimization algorithms, are laborious and time-consuming. Furthermore, their functionality is restricted to phase calibration, leaving amplitude errors uncalibrated. In this work, we present what is believed to be a novel phase and amplitude calibration method for integrated OPAs based on a linear matrix algorithm. This method offers a non-iterative and more efficient alternative. Numerical simulation results show that the proposed method requires only N measurements to calibrate an N -element integrated OPA, whereas the well-known stochastic parallel gradient descent (SPGD) algorithm requires about 6 N −8 N measurements. The proposed method offers this approach for fast and accurate phase and amplitude calibration of integrated OPAs.
Förderung
- National Natural Science Foundation of China
- Department of Science and Technology of Hunan Province
- National University of Defense Technology
Zitieren
APA
Zhang, L., Liu, R., Wang, X., Zhang, Y., Guo, Z., Zhao, X., Cao, Y., & Han, X. (2026). High-efficiency, non-iterative phase and amplitude calibration method for integrated optical phased arrays. Applied Optics, 65(24), 8432. https://doi.org/10.1364/ao.609254
Vancouver
Zhang L, Liu R, Wang X, Zhang Y, Guo Z, Zhao X, et al. High-efficiency, non-iterative phase and amplitude calibration method for integrated optical phased arrays. Applied Optics. 2026;65(24):8432. doi:10.1364/ao.609254
BibTeX
@article{Zhang2026,
author = {Zhang, Lin and Liu, Ruyuan and Wang, Xiaobin and Zhang, Yuqiu and Guo, Zichen and Zhao, Xu and Cao, Yang and Han, Xiang’e},
title = {High-efficiency, non-iterative phase and amplitude calibration method for integrated optical phased arrays},
journal = {Applied Optics},
year = {2026},
volume = {65},
number = {24},
pages = {8432},
doi = {10.1364/ao.609254}
}
EUVIMED