High-accuracy underwater binocular line-laser 3D measurement via multi-medium refractive calibration
Applied Optics · 10.08.2026 · 65 (23) · 7720
DOI: 10.1364/ao.603087 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Optics, online erschienen am 31.07.2026. Verfasst von Qiang Shen und 6 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Major Science and Technology Project of China, Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China, Central Guided Local Science and Technology Development Fund Project of Hubei Province.
Abstract (Originalsprache)
Underwater optical three-dimensional (3D) measurement is fundamentally challenged by multi-medium refraction at air–glass–water interfaces, which invalidates the conventional central projection model and significantly degrades reconstruction accuracy. To address this issue, we propose an underwater binocular line-laser 3D measurement method that combines explicit refractive imaging modeling, refractive parameter calibration, and subpixel laser-stripe reconstruction. First, an underwater binocular line-laser imaging model is established for the air–glass–water optical path, in which the refractive ray paths are described using Snell’s law, and the key parameters include the relative pose of the two cameras, the interface normal, the distance from the camera center to the glass interface, the glass thickness, and the refractive indices of the involved media. Second, a multi-objective optimization framework is developed to calibrate the refractive parameters by jointly minimizing the shortest distance between refracted binocular rays and enforcing geometric constraints of calibration-board corners, including equal edge length, coplanarity, and orthogonality. Third, for underwater line-laser reconstruction, a subpixel laser-stripe processing strategy is introduced by combining Laplacian-of-Gaussian filtering, zero-crossing edge localization, inscribed-circle fitting of stripe boundaries, B-spline smoothing, and 3D reconstruction under the refractive epipolar constraint. Simulation and experimental results demonstrate that the proposed calibration method substantially improves robustness against image noise. In real experiments, the developed underwater binocular line-laser scanner achieves a measurement accuracy better than 0.14 mm within a measurement range of 400 mm, showing its effectiveness for high-accuracy underwater 3D measurement.
Förderung
- National Major Science and Technology Project of China
- Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China
- Central Guided Local Science and Technology Development Fund Project of Hubei Province
- National Natural Science Foundation of China
Zitieren
APA
Shen, Q., Li, W., Gao, C., Zhang, J., Liu, Y., Li, T., & Li, W. (2026). High-accuracy underwater binocular line-laser 3D measurement via multi-medium refractive calibration. Applied Optics, 65(23), 7720. https://doi.org/10.1364/ao.603087
Vancouver
Shen Q, Li W, Gao C, Zhang J, Liu Y, Li T, et al. High-accuracy underwater binocular line-laser 3D measurement via multi-medium refractive calibration. Applied Optics. 2026;65(23):7720. doi:10.1364/ao.603087
BibTeX
@article{Shen2026,
author = {Shen, Qiang and Li, Wenpan and Gao, Chao and Zhang, Jinhua and Liu, Yuqi and Li, Tianxiong and Li, Wenlong},
title = {High-accuracy underwater binocular line-laser 3D measurement via multi-medium refractive calibration},
journal = {Applied Optics},
year = {2026},
volume = {65},
number = {23},
pages = {7720},
doi = {10.1364/ao.603087}
}
EUVIMED