Excitation strategy and experimental validation of nitric oxide laser-induced fluorescence diagnostics in high-enthalpy flow
Applied Optics · 01.08.2026 · 65 (22) · 7503
DOI: 10.1364/ao.600784 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Optics, online erschienen am 27.07.2026. Verfasst von Xun Yuan und 9 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Key R&D Program of China, Open Foundation of Aerodynamics Laboratory of CAAA.
Abstract (Originalsprache)
High-enthalpy flow is characterized by low number density and a wide temperature range, which pose significant challenges for nitric oxide laser-induced fluorescence (NO-LIF) measurements. Selecting a suitable excitation wavelength is both important and challenging. To address the lack of systematic excitation wavelength selection for NO-LIF diagnostics in high-enthalpy flow, this paper develops an excitation wavelength selection strategy based on the flow environment and the spectral characteristics of NO molecules. This strategy uses an excitation wavelength quality factor S ( λ , T ) to evaluate the performance of each rotational line in the γ (0,0) band at different temperatures, including fluorescence intensity, temperature sensitivity, and absorption attenuation. Moreover, this factor can be feedback-corrected according to experimental results, thereby meeting the requirements of various flow diagnostics. Validation tests were conducted in the high-enthalpy flow of an arc-heated wind tunnel. The results show that the excitation wavelength selected based on this strategy exhibits excellent performance in fluorescence intensity, temperature sensitivity, and absorption attenuation.
Förderung
- National Key R&D Program of China
- Open Foundation of Aerodynamics Laboratory of CAAA
Zitieren
APA
Yuan, X., Yu, X., Yang, C., Peng, J., Cao, Z., Luo, X., Liu, W., Zhang, X., Zeng, H., & Ou, D. (2026). Excitation strategy and experimental validation of nitric oxide laser-induced fluorescence diagnostics in high-enthalpy flow. Applied Optics, 65(22), 7503. https://doi.org/10.1364/ao.600784
Vancouver
Yuan X, Yu X, Yang C, Peng J, Cao Z, Luo X, et al. Excitation strategy and experimental validation of nitric oxide laser-induced fluorescence diagnostics in high-enthalpy flow. Applied Optics. 2026;65(22):7503. doi:10.1364/ao.600784
BibTeX
@article{Yuan2026,
author = {Yuan, Xun and Yu, Xin and Yang, Chaobo and Peng, Jiangbo and Cao, Zhen and Luo, Xinguang and Liu, Wenbei and Zhang, Xuteng and Zeng, Hui and Ou, Dongbin},
title = {Excitation strategy and experimental validation of nitric oxide laser-induced fluorescence diagnostics in high-enthalpy flow},
journal = {Applied Optics},
year = {2026},
volume = {65},
number = {22},
pages = {7503},
doi = {10.1364/ao.600784}
}