Distortion calibration method in a hyperspectral imaging system using Zernike polynomials for a rectangular aperture
Applied Optics · 20.06.2026 · 65 (18) · 6242
DOI: 10.1364/ao.598835 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Optics, online erschienen am 15.06.2026. Verfasst von Tri Nguyen und 2 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Ministry of Trade, Industry and Energy, National Research Foundation of Korea.
Abstract (Originalsprache)
We present what is believed to be a novel method to model spectral and spatial distortions for hyperspectral imaging (HSI) data. Conventional algorithms that express these distortions using quadratic polynomials often suffer from inaccurate reconstruction near the image edge when the distortions are severe. Therefore, we propose to use orthogonal Zernike polynomials for a rectangular aperture to express the spectral (smile) and spatial (keystone) displacements owing to their rigorous mathematical properties. Using simulation data, we first validated that the proposed approach could reconstruct full-field distortions with subpixel accuracy, even when a limited number of discrete calibration points are available. In the experiment, we use a mercury light source combined with a precise line pattern target to simultaneously measure the smile and keystone of the HSI system. The distortions are described by Zernike polynomials for the rectangular aperture [demonstrated in simulations to achieve a reconstruction root mean square error (RMSE) of 0.193 pixels in the spectral direction and 0.441 pixels in the spatial direction using fiducial points], and a correction coefficient matrix is found to map pixels to the target location. The correction results with different Zernike terms are evaluated using the mean wavelength error (MWE) parameter and the mean spatial shift (MSS). Experimental results show that the proposed method corrected the HSI system developed in our laboratory with an MWE of 0.017 nm and an MSS of 0.189 pixels.
Förderung
- Ministry of Trade, Industry and Energy
- National Research Foundation of Korea
Zitieren
APA
Nguyen, T., Vu, H., & Lee, J. (2026). Distortion calibration method in a hyperspectral imaging system using Zernike polynomials for a rectangular aperture. Applied Optics, 65(18), 6242. https://doi.org/10.1364/ao.598835
Vancouver
Nguyen T, Vu H, Lee J. Distortion calibration method in a hyperspectral imaging system using Zernike polynomials for a rectangular aperture. Applied Optics. 2026;65(18):6242. doi:10.1364/ao.598835
BibTeX
@article{Nguyen2026,
author = {Nguyen, Tri and Vu, Huy and Lee, Joohyung},
title = {Distortion calibration method in a hyperspectral imaging system using Zernike polynomials for a rectangular aperture},
journal = {Applied Optics},
year = {2026},
volume = {65},
number = {18},
pages = {6242},
doi = {10.1364/ao.598835}
}