EUVIMEDEUVIMED entdecken
Crossref

High-sensitivity finger joint angle sensor utilizing a Mach–Zehnder interferometer with a five-cladding fiber

Xiaojun Zhu, Yan Wang, Jiajia Wan, Junjie Wang, Jicong Zhao

Applied Optics · 20.06.2026 · 65 (18) · 6341

DOI: 10.1364/ao.595541 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 16.06.2026. Verfasst von Xiaojun Zhu und 4 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Postgraduate Research Practice Innovation Program of Jiangsu Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We propose a finger joint angle sensor based on a Mach–Zehnder interferometer (MZI) with a five-cladding fiber (FCF). The sensor is fabricated by fusion splicing an FCF between two single-mode fibers (SMFs). When the finger joint flexes or extends, the optical path difference between the core mode and cladding modes of the sensor changes accordingly, which causes the sensor to exhibit a wavelength shift. The sensor is encapsulated in a thin hose, embedded in a knitted finger sleeve, and attached to a mechanical finger device to measure the joint bending angle. Experimental results show that the sensor can measure the bending angle of the finger joint within the 0°–100° range. When the finger joint bending angle changes from 40° to 90°, the angle sensitivity can reach −995pm/ ∘ , with a linearity of 0.997. In addition, the sensor shows low temperature sensitivity in the temperature range of 20°C–80°C, and its maximum temperature sensitivity is only −0.01099nm/ ∘ C. The proposed FCF bending sensor has the advantages of high bending sensitivity, low cost, and simple preparation. It has potential application prospects in the field of human joint monitoring and provides a simple and feasible technical solution for finger joint movement detection.

Förderung

  • Postgraduate Research Practice Innovation Program of Jiangsu Province

Zitieren

APA

Zhu, X., Wang, Y., Wan, J., Wang, J., & Zhao, J. (2026). High-sensitivity finger joint angle sensor utilizing a Mach–Zehnder interferometer with a five-cladding fiber. Applied Optics, 65(18), 6341. https://doi.org/10.1364/ao.595541

Vancouver

Zhu X, Wang Y, Wan J, Wang J, Zhao J. High-sensitivity finger joint angle sensor utilizing a Mach–Zehnder interferometer with a five-cladding fiber. Applied Optics. 2026;65(18):6341. doi:10.1364/ao.595541

BibTeX
@article{Zhu2026,
  author = {Zhu, Xiaojun and Wang, Yan and Wan, Jiajia and Wang, Junjie and Zhao, Jicong},
  title = {High-sensitivity finger joint angle sensor utilizing a Mach–Zehnder interferometer with a five-cladding fiber},
  journal = {Applied Optics},
  year = {2026},
  volume = {65},
  number = {18},
  pages = {6341},
  doi = {10.1364/ao.595541}
}
Kostenlos starten →