EUVIMEDEUVIMED entdecken
Crossref

Field-validated high-sensitivity distributed mass sensing using a triple-taper-based Φ-OTDR sensor

Mohammad Fadil Sawli, Alireza Khorsandi, Hamidreza Karimi-Alavijeh

Applied Optics · 01.06.2026 · 65 (16) · 5510

DOI: 10.1364/ao.591725 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 27.05.2026. Verfasst von Mohammad Fadil Sawli und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We propose a phase-sensitive optical time-domain reflectometry (Φ-OTDR) sensor using a triple-tapered fiber structure to enhance loading mass detection sensitivity. The sensor features a 5 m sensing region with three sequential tapers reduced to a 20 µm diameter, strengthening light mechanical interaction compared to a non-tapered fiber. Experimental results show a maximum signal-to-noise ratio (SNR) of 27.16 dB, representing an approximately 30% improvement over a standard 5 m non-tapered sensor, along with a maximum detectable phase shift of 0.168±0.009rad and a mass sensitivity of 0.601±0.017µs/g. Refractive index variations extracted from the Φ-OTDR signal closely agree with theoretical predictions, yielding an average percentage error (APE) of 7.592×10 −3 %. Field validation further confirmed reliability, achieving strong correlation with laboratory benchmarks (RMSE=0.826, MAPE=1.92%), demonstrating consistent and accurate loaded-mass estimation. Field experiments validated sensor performance under realistic conditions using calibrated load masses of simulated animals on sand surfaces above the embedded fiber. The sensor accurately detected and quantified unknown loads, showing excellent agreement between predicted and realistic measurements. These results highlight the enhanced sensitivity, accuracy, and stability of the proposed triple-taper Φ-OTDR sensor for advanced distributed sensing applications.

Zitieren

APA

Sawli, M. F., Khorsandi, A., & Karimi-Alavijeh, H. (2026). Field-validated high-sensitivity distributed mass sensing using a triple-taper-based Φ-OTDR sensor. Applied Optics, 65(16), 5510. https://doi.org/10.1364/ao.591725

Vancouver

Sawli MF, Khorsandi A, Karimi-Alavijeh H. Field-validated high-sensitivity distributed mass sensing using a triple-taper-based Φ-OTDR sensor. Applied Optics. 2026;65(16):5510. doi:10.1364/ao.591725

BibTeX
@article{Sawli2026,
  author = {Sawli, Mohammad Fadil and Khorsandi, Alireza and Karimi-Alavijeh, Hamidreza},
  title = {Field-validated high-sensitivity distributed mass sensing using a triple-taper-based Φ-OTDR sensor},
  journal = {Applied Optics},
  year = {2026},
  volume = {65},
  number = {16},
  pages = {5510},
  doi = {10.1364/ao.591725}
}
Kostenlos starten →