EUVIMEDEUVIMED entdecken
Crossref

Optimization, analysis, and thermal performance enhancement of the cooling flow channel for a condenser mirror

Jiaming Li, Ha Wang, He Wang, Kai Zhang, Yuan Yao, Yutian Zhang, Songtao Hao, Xiaolin Xie, Hemeng Qu, Jizhen Zhang

Applied Optics · 01.02.2025 · 64 (4) · 1036

DOI: 10.1364/ao.546981 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 29.01.2025. Verfasst von Jiaming Li und 9 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: Jilin Provincial Scientific and Technological Development Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Condenser mirrors with the ellipsoidal surface type are widely used in laser illuminating systems. Nonetheless, thermal absorption in optical components is unavoidable because of high-energy lasers, leading to a decline in surface shape accuracy. In extreme instances, this can shorten the operational longevity or impair the system’s focusing capabilities. Currently, water cooling is a major technical approach for controlling the thermal deformation of condenser mirrors. This paper proposes an efficient cooling flow channel based on topology optimization methods for high-gradient ellipsoidal optical mirrors. Firstly, topology optimization of the cooling flow channel was performed with the objective function of minimizing average temperature and entransy dissipation. Next, the influence of different design parameters on the optimization results was investigated, and the optimal topological structure was obtained. Then, a thermal–fluid–solid coupled simulation was carried out for a three-dimensional model of the water-cooled condenser mirror to verify the topology optimization design. The results show that when the inlet flow rate is 2.82×10 −4 m 3 /s, the surface shape accuracy of the water-cooled condenser mirror (RMS 213.79 nm) equipped with the topology optimization cooling flow channel is reduced by 22.96% compared to that of the water-cooled condenser mirror (RMS 277.66 nm) with the traditional spiral cooling flow channel. Finally, the manufacturability of the optimized model was verified by selective laser melting technology and x-ray detection.

Förderung

  • Jilin Provincial Scientific and Technological Development Program

Zitieren

APA

Li, J., Wang, H., Wang, H., Zhang, K., Yao, Y., Zhang, Y., Hao, S., Xie, X., Qu, H., & Zhang, J. (2025). Optimization, analysis, and thermal performance enhancement of the cooling flow channel for a condenser mirror. Applied Optics, 64(4), 1036. https://doi.org/10.1364/ao.546981

Vancouver

Li J, Wang H, Wang H, Zhang K, Yao Y, Zhang Y, et al. Optimization, analysis, and thermal performance enhancement of the cooling flow channel for a condenser mirror. Applied Optics. 2025;64(4):1036. doi:10.1364/ao.546981

BibTeX
@article{Li2025,
  author = {Li, Jiaming and Wang, Ha and Wang, He and Zhang, Kai and Yao, Yuan and Zhang, Yutian and Hao, Songtao and Xie, Xiaolin and Qu, Hemeng and Zhang, Jizhen},
  title = {Optimization, analysis, and thermal performance enhancement of the cooling flow channel for a condenser mirror},
  journal = {Applied Optics},
  year = {2025},
  volume = {64},
  number = {4},
  pages = {1036},
  doi = {10.1364/ao.546981}
}
Kostenlos starten →