EUVIMEDEUVIMED entdecken
Crossref

Automatic and accurate phase aberration compensation for a digital holographic microscopy system based on one-dimensional weighted curve fitting

Zheng Wang, Mingjie Jiao, Feng Liu, Biao Wang, Xueying Jin

Applied Optics · 10.02.2025 · 64 (5) · 1167

DOI: 10.1364/ao.545234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 04.02.2025. Verfasst von Zheng Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Anhui Provincial Department of Science and Technology, Fundamental Research Funds for the Central Universities.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We propose an automatic and accurate phase aberration compensation method for a digital holographic microscopy system. The phase aberrations are extracted by the one-dimensional weighted curve fitting method where the pre-compensated phase is obtained by the phase segmentation method based on the median absolute deviation (MAD) criterion, and the weights of the object phase and the background phase are acquired such that the object phase can be eliminated. Our approach does not require manual selection of area with no sampling and prior optical system parameters. Numerical simulation verifies that the proposed method is more accurate than the general one-dimensional curve fitting method. Experimental measurements demonstrate the effectiveness and applicability of the proposed method in USAF1951 resolution plates and living cells including BCAF breast cancer cells and HCT116 colon cancer cells.

Förderung

  • National Natural Science Foundation of China
  • Anhui Provincial Department of Science and Technology
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Wang, Z., Jiao, M., Liu, F., Wang, B., & Jin, X. (2025). Automatic and accurate phase aberration compensation for a digital holographic microscopy system based on one-dimensional weighted curve fitting. Applied Optics, 64(5), 1167. https://doi.org/10.1364/ao.545234

Vancouver

Wang Z, Jiao M, Liu F, Wang B, Jin X. Automatic and accurate phase aberration compensation for a digital holographic microscopy system based on one-dimensional weighted curve fitting. Applied Optics. 2025;64(5):1167. doi:10.1364/ao.545234

BibTeX
@article{Wang2025,
  author = {Wang, Zheng and Jiao, Mingjie and Liu, Feng and Wang, Biao and Jin, Xueying},
  title = {Automatic and accurate phase aberration compensation for a digital holographic microscopy system based on one-dimensional weighted curve fitting},
  journal = {Applied Optics},
  year = {2025},
  volume = {64},
  number = {5},
  pages = {1167},
  doi = {10.1364/ao.545234}
}
Kostenlos starten →