EUVIMEDEUVIMED entdecken
Crossref

Interferometric measurement of the radius of curvature based on axial displacement from a confocal position and corresponding defocus wavefront

Yiming Liu, Jinpeng Li, Yao Hu, Shaohui Zhang, Zichen Wang, Chuheng Xu, Shuai Yang, Weiqian Zhao, Qun Hao

Applied Optics · 10.07.2023 · 62 (20) · 5443

DOI: 10.1364/ao.495703 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 05.07.2023. Verfasst von Yiming Liu und 8 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Strategic Priority Research Program of the Chinese Academy of Sciences, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The radius of curvature ( R ) is a fundamental parameter of spherical optical surfaces. The measurement range of the widely adopted traditional interferometric method is limited by the length of the precision linear guide rail carrying the measured surface from the cat’s eye to the confocal position, and the test result is vulnerable to airflow and vibration in the test environment. An interferometric method is proposed for the radius measurement of spherical surfaces based on a small axial moving distance and the corresponding defocus wavefront to eliminate the dependence on a long guide rail and extend the measuring range. To eliminate the influence of the test environment and calculate the R , a defocus transform algorithm is proposed to instantaneously measure the defocus wavefront from a single interferogram. Numerical simulations theoretically demonstrate that there is no limit to the measurement range of this method because only a short distance of the measured mirror must be moved. A spherical mirror with a radius of curvature of 101.6087 mm is experimentally tested, and the relative measurement error is 0.037%. This method can achieve high accuracy for optical shops and greatly increase the measurement range of the interferometric method without additional equipment.

Förderung

  • National Key Research and Development Program of China
  • Strategic Priority Research Program of the Chinese Academy of Sciences
  • National Natural Science Foundation of China
  • Nanjing International Science and Technology Cooperation Project

Zitieren

APA

Liu, Y., Li, J., Hu, Y., Zhang, S., Wang, Z., Xu, C., Yang, S., Zhao, W., & Hao, Q. (2023). Interferometric measurement of the radius of curvature based on axial displacement from a confocal position and corresponding defocus wavefront. Applied Optics, 62(20), 5443. https://doi.org/10.1364/ao.495703

Vancouver

Liu Y, Li J, Hu Y, Zhang S, Wang Z, Xu C, et al. Interferometric measurement of the radius of curvature based on axial displacement from a confocal position and corresponding defocus wavefront. Applied Optics. 2023;62(20):5443. doi:10.1364/ao.495703

BibTeX
@article{Liu2023,
  author = {Liu, Yiming and Li, Jinpeng and Hu, Yao and Zhang, Shaohui and Wang, Zichen and Xu, Chuheng and Yang, Shuai and Zhao, Weiqian and Hao, Qun},
  title = {Interferometric measurement of the radius of curvature based on axial displacement from a confocal position and corresponding defocus wavefront},
  journal = {Applied Optics},
  year = {2023},
  volume = {62},
  number = {20},
  pages = {5443},
  doi = {10.1364/ao.495703}
}
Kostenlos starten →