EUVIMEDEUVIMED entdecken
Crossref

Rotation axis calibration of a 3D scanning system based on dual-turntable angle cancellation

Limei Song, Zhenning Liu, Yunpeng Li, Qinghua Guo, Jinshen He, Jipeng Zhang

Applied Optics · 01.02.2023 · 62 (4) · 894

DOI: 10.1364/ao.477620 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Optics, online erschienen am 23.01.2023. Verfasst von Limei Song und 5 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Program for Innovative Research Team in University of Tianjin, Tianjin Science and Technology Popularization Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rotation axis calibration is crucial for high-precision automatic point cloud stitching in turntable-based 3D scanning systems. To achieve a 360° sampling with a 2D calibrator in rotation axis calibration, this paper proposes a dual-turntable angle cancellation (DTAC) method. DTAC introduces an auxiliary turntable to keep a proper relative angle between the 3D sensor and the calibrator during the calibration process. The auxiliary turntable rotates at the same and opposite angle as the main turntable and cancels the increment of the relative angle. By projecting the feature points on the planar calibrator from real-world space to virtual calibration space, the projected points all share the same rotation axis of the main turntable. Further, a layered circle center extraction (LCCE) algorithm is applied to deal with outlier data points. The algorithm uses a two-step robust estimation strategy combining RANSAC circle fitting with a median noise filter for circle center selection. The standard ball reconstruction experiment shows that the 3D system calibrated by the method achieves a mean absolute error of 0.022 mm and root mean square error of 0.025 mm within the measurement distance of 60–70 cm. Point cloud stitching experiments of different types of objects show that our method outperforms other state-of-the-art methods in stitching accuracy. The DTAC method and LCCE algorithm can improve turntable-based 3D scanning systems.

Förderung

  • National Natural Science Foundation of China
  • Program for Innovative Research Team in University of Tianjin
  • Tianjin Science and Technology Popularization Project

Zitieren

APA

Song, L., Liu, Z., Li, Y., Guo, Q., He, J., & Zhang, J. (2023). Rotation axis calibration of a 3D scanning system based on dual-turntable angle cancellation. Applied Optics, 62(4), 894. https://doi.org/10.1364/ao.477620

Vancouver

Song L, Liu Z, Li Y, Guo Q, He J, Zhang J. Rotation axis calibration of a 3D scanning system based on dual-turntable angle cancellation. Applied Optics. 2023;62(4):894. doi:10.1364/ao.477620

BibTeX
@article{Song2023,
  author = {Song, Limei and Liu, Zhenning and Li, Yunpeng and Guo, Qinghua and He, Jinshen and Zhang, Jipeng},
  title = {Rotation axis calibration of a 3D scanning system based on dual-turntable angle cancellation},
  journal = {Applied Optics},
  year = {2023},
  volume = {62},
  number = {4},
  pages = {894},
  doi = {10.1364/ao.477620}
}
Kostenlos starten →