Prediction of the Fate of Spent Engine Oil Spill from a Base Transceiver Station in the Unsaturated Zone
Journal of Environmental Studies · 2020
DOI: 10.13188/2471-4879.1000028 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Studies, 2020. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
In this study, Response Surface Methodology (RSM) was employed to predict the amount of spent engine oil leached/retained in the soil after spilling from generators in a telecommunication base station. The experiment was performed at 27 runs based on RSM design with three independent variables, i.e., soil depth, rainfall intensity and contaminant volume. The ANOVA results show that at the 95% confi dence level, the interactions of contaminant volume with soil depth and rainfall intensity signifi cantly affect the amount of spent engine oil leached/retained. Additionally, a second-order polynomial equation was developed to relate the leached/retained used oil and the independent variables. An optimization carried out showed that the contaminant volume decreases with the amount of spent oil leached. At 50 ml contaminant volume, the amount of oil leached gave 2675.55 mg/l while soil depth is 90cm at a rainfall intensity of 5mm/hr, while 9033.68% of oil is retained in the soil. Minimizing the amount of spent engine oil retained at 4550.4%, the contaminant volume is given as 50ml, and soil depth shows 53.5cm while 7092.1mg/l was leached. The model was validated by comparing experimental data and predicted values, which showed a good agreement as well as %error computation. The fi tted model shows a good agreement between predicted and experimental data at R2 of 0.9587 and 0.9849 for used oil leached/retained. The analysis shows there is a good relationship between the actual and predicted lached and retained concentrations producing a line of best fi t with high correlation coeffi cient and predictive relevance. This implies that the developed model can adequately predict the transport of spent engine oil in the unsaturated zone. Citation: Theophilus N, Akaranta O, Ugwoha E. Prediction of the Fate of Spent Engine Oil Spill from a Base Transceiver Station in the Unsaturated Zone. J Environ Stud. 2020;6(1): 9. J Environ Stud 6(1): 9 (2020) Page 02 ISSN: 2471-4879 Soil samples around base transceiver station sites in AkwaIbom state were collected using a fabricated auger rig. However, the geographical coordinates of the BTS site where the inherent soil samples were collected are between latitude 4.9057° N and longitude 7.8537° E. Th is location was selected based on the occurrence of oil spill from diesel generators at the BTS and accessibility to the spilled sites (see map of the BTS in Figure1). Collection of soil samples and grain size analysis A galvanized steel mesocosm was constructed to collect soil undisturbed. Th ree sets of 300 mm, 600 mm and 900mm height diameter galvanized steel pipes were constructed to produce the mesocosm used in this study. Before the collection of soil samples at the base transceiver station sites, the topsoil was cleared to a depth of 20 cm [11]. Th e galvanized steel mesocosm, hammered with the aid of a fabricated auger rig, was used to directly collect undisturbed soil samples, as seen in (Figure 2). Five (5) samples were obtained from the study location. Th e collected soil samples were further analyzed in the laboratory to determine the predominant soil type at the BTS in each site where the samples were obtained. Th e soil samples were analyzed and predominant soil types obtained utilizing grain size analysis using the hydrometer method. Th e laboratory analysis was carried out at the Civil and Environmental Engineering Laboratory, University of Port Harcourt. Th e soil was characterized and classifi ed into clay, silt, sand, and gravel as shown in (Table 1). For every randomly selected BTS within the study location, the soil samples were extracted at various depths of 30, 60 and 90 cm, as is consistent with the design of the experiment. For every 30 cm depth, 9 samples of undisturbed soil were collected. Similarly, for each of 60 cm and 90 cm depth, 9 samples of undisturbed soil were collected. Th e collected soil samples were transported for contamination, rainfall simulation and other relevant experiments. Figure 1: Map of the study location showing the BTS. Figure 2: (a) Galvanized steel mesocosm. (b) Collection of undisturbed soil sample. BTS site Coordinates Clay Silt Sand Gravel Ikot Ekpene 5.1744° N, 7.7145° E Oron 4.8074° N, 8.2377° E Uyo 5.0377° N, 7.9128° E Abak 5.0033° N, 7.7743° E Eket 4.6467° N, 7.9429° E Table 1: Description of sampling sites and soil properties. Citation: Theophilus N, Akaranta O, Ugwoha E. Prediction of the Fate of Spent Engine Oil Spill from a Base Transceiver Station in the Unsaturated Zone. J Environ Stud. 2020;6(1): 9. J Environ Stud 6(1): 9 (2020) Page 03 ISSN: 2471-4879 Design of experiment A 33 full factorial design of experiment was applied to investigate the infl uence of the independent variables on leached and retained amount of spent engine oil in the soil. Factor levels were chosen by considering the operational limits of the experimental setup. Response Surface Methodology (RSM) was employed in the design of experiment. Th e experimental design was carried out in XLSTAT 2019 while the response surface analysis was computed using design expert version 11 by stat-ease. Th e independent parameters which include the contaminant volume, rainfall intensity and soil depth were selected using a 33 experimental design in XLSTAT 2019 soft ware. Th e selected rainfall intensity values were chosen to replicate rainfall patterns recorded in each of the considered sites within the study location, as was obtained from the Nigerian Meteorological Agency (NIMET). Collection of spent engine oil Figure 3: Collection of spent engine oil sample during maintenance of diesel generator used at BTS site. Figure 4: (a) Rainfall simulation set-up and (b) Contamination of undisturbed soil samples in galvanized steel mesocosms and collection of leachates. Figure 5: Eff ect of rainfall intensity and contaminant volume on leached (A) 3D surface plot (B) 2D contour plot. Citation: Theophilus N, Akaranta O, Ugwoha E. Prediction of the Fate of Spent Engine Oil Spill from a Base Transceiver Station in the Unsaturated Zone. J Environ Stud. 2020;6(1): 9. J Environ Stud 6(1): 9 (2020) Page 04 ISSN: 2471-4879 Th e spent engine oil was collected during the frequent maintenance of the diesel generators used to power the Base Transceiver Station sites (BTS). Th e spent engine oil sample was collected using plastic bottles. Th e bottles were initially rinsed with the waste engine oil before the actual collection as shown in (Figure 3). Th e spent engine oil was the contaminant utilized in the experiment. Experimental set-up and procedures Th e experimental set-up consists of 2 major aspects (1) Rainfall simulator set-up, and (2) Mesocosm set-up. Rainfall simulator set-up: Th e rain simulator was made of a rubber tank of 1000L capacity constructed to imitate the rainfall pattern of the study location using the data obtained from NIMET. Th e obtained rainfall data were used in calibrating the rainfall simulator to produce 5 mm/hr, 7.5 mm/hr and 10 mm/hr rainfall intensities, for diff erent volumes of the spent engine oil. Also, a 37.5 mm horsepower surface water pump was utilized for continuous refi lling of the tank using 37.5 inches PVC pipe, in conjunction with some plumbing fi ttings like union, valves, adaptors, pipes and elbows. Th ree shower heads were also connected using 37.5 to 12.5 inches reducers, 12.5 inches PVC pipes, union, valves, elbow, adaptors and plug and cap. Th e showerheads were mounted on a 25 mm diameter galvanized steel pipe welded to a 20 mm steel base plate to ensure the stability of the shower headstands. Also, 3 transparent 5L plastic calibrated buckets were used to collect the water during the simulation. Two measuring plastic cylinders (1000L and 2000L) were used to measure the amount of rainfall. A stopwatch was used to measure the duration of rainfall when the valves were opened for water infl ow. Simulated rainfall at various intensities (5 mm/hr, 7.5 mm/hr, 10 mm/hr) and volume of contaminants (50 ml, 200 ml, 350 ml) were introduced to the undisturbed soil in the mesocosm. Th erefore, the intensity of the simulated rainfall was obtained as the height of rainfall collected within a 150 mm diameter pipe per hour of rainfall (Figure 4a). Mesocosm set-up: Some galvanized steel mesocosms were constructed to collect soil samples in an undisturbed condition. Th ree sets of galvanized steel pipes of 300mm, 600mm and 900mm diameters were constructed for use as mesocosm. Th e waste engine oil was collected using plastic bottles during the frequent maintenance of the diesel generators used to power the Base Transceiver Station sites (BTS) and added separately in the diff erent containers as stated in the experimental design and thoroughly mixed and left undisturbed for 48 hours to allow the volatilization of toxic compounds of the oil [12]. Following the rainfall simulation explained in the previous subsection. Clips were employed to hold the mesocosms in place on a table while being contaminated and rainfall patterns simulated. Th e 600 mm diameter holes were constructed to install the 600 mm and 900 mm high mesocosms that have the same diameter as the constructed hole. Th e base of the mesocosm was protected with a net to prevent erosion and sieve the washout with the aid of a fabricated galvanized steel clips. Leachates were collected using plastic containers placed at the base of the elevated steel mesocosms following the 27 experimental runs (Figure 4b). Determination soil hydrocarbon extraction water content: Th is test was used to determine the weight of a wet sample along with the container for 24 hours in an oven and then determine the weight of Runs X1 (ml) X2 (mm/hr) X3 (cm) 1 50 5 30 2 200 5 30 3 350 5 30 4 50 7.5 30 5 200 7.5 30 6 350 7.5 30 7 50 10 30 8 200 10 30 9 350 10 30 10 50 5 60 11 200 5 60 12 350 5 60 13 50 7.5 60 14 200 7.5 60 15 350 7.5 60 16 50 10 60 17 200 10 60 18 350 10 60 19 50 5 90 20 200 5 90 21 350 5 90 22 50 7.5 90 23
Zitieren
APA
(2020). Prediction of the Fate of Spent Engine Oil Spill from a Base Transceiver Station in the Unsaturated Zone. Journal of Environmental Studies. https://doi.org/10.13188/2471-4879.1000028
Vancouver
Prediction of the Fate of Spent Engine Oil Spill from a Base Transceiver Station in the Unsaturated Zone. Journal of Environmental Studies. 2020. doi:10.13188/2471-4879.1000028
BibTeX
@article{euvimed2020,
title = {Prediction of the Fate of Spent Engine Oil Spill from a Base Transceiver Station in the Unsaturated Zone},
journal = {Journal of Environmental Studies},
year = {2020},
doi = {10.13188/2471-4879.1000028}
}
EUVIMED