Impact of Hybrid Triple Signal Filters on Magnetic Resonance Image Uniformity Under Challenging Scanning Conditions
Investigative Magnetic Resonance Imaging · 2026 · 30 (2) · 125
DOI: 10.13104/imri.2026.0011 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Magnetic Resonance Imaging, 2026. Verfasst von Hamza Arjah und 3 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
Magnetic resonance imaging (MRI) signal uniformity is a critical issue affecting the quality of MRI images.MRI vendors have proposed signal filters to enhance image uniformity and combining them can significantly increase the percentage of image uniformity (PIU).The use of individual or multiple filters can also introduce changes that affect overall image quality while addressing non-uniformity artifacts.However, under challenging scanning conditions, image uniformity is more severely affected, and correction becomes more difficult.Materials and Methods: Scanner performance was evaluated using phantom-based metrics, including the modulation transfer function (MTF), signal-to-noise ratio (SNR), PIU, contrast-to-noise ratio (CNR), and percentage of signal ghosting (PSG).Clinical image quality was quantified using fat PIU (PIUfat) and fat SNR (SNRfat), whereas the diagnostic appearance was assessed qualitatively by two radiologists.
Results
Phantom-based assessments showed PIU enhancement of the T1 sequence in three signal filters (3SFs) compared with that of pre-scan normalize (PSN).The phantom PIU of T1 increased from 87.3% to 92.12%.In comparison, T2 showed a slight reduction in PIU for 3SFs compared with that for PSN, from 93.19% to 91.45%, respectively.For the clinical images, PIUfat increased significantly across all sequences (p < 0.001), increasing from 57% in PSN to 87% in 3SFs, and the diagnostic appearance improved.However, MTF, SNR, and PSG were preserved, whereas the CNR was significantly degraded in 3SFs compared to that of PSN (p < 0.001).
Conclusion
3SFs enhances PIU, MTF, and qualitative assessments of diagnostic appearance while preserving PSG and SNR but degrades CNR.
Zitieren
APA
Arjah, H., Qasrawi, R., ALMasri, H., & Mousa, M. (2026). Impact of Hybrid Triple Signal Filters on Magnetic Resonance Image Uniformity Under Challenging Scanning Conditions. Investigative Magnetic Resonance Imaging, 30(2), 125. https://doi.org/10.13104/imri.2026.0011
Vancouver
Arjah H, Qasrawi R, ALMasri H, Mousa M. Impact of Hybrid Triple Signal Filters on Magnetic Resonance Image Uniformity Under Challenging Scanning Conditions. Investigative Magnetic Resonance Imaging. 2026;30(2):125. doi:10.13104/imri.2026.0011
BibTeX
@article{Arjah2026,
author = {Arjah, Hamza and Qasrawi, Radwan and ALMasri, Hussein and Mousa, Mahmoud},
title = {Impact of Hybrid Triple Signal Filters on Magnetic Resonance Image Uniformity Under Challenging Scanning Conditions},
journal = {Investigative Magnetic Resonance Imaging},
year = {2026},
volume = {30},
number = {2},
pages = {125},
doi = {10.13104/imri.2026.0011}
}
EUVIMED