Ultrashort Echo Time and Zero Echo Time MRI and Their Applications at High Magnetic Fields: A Literature Survey
Investigative Magnetic Resonance Imaging · 2024 · 28 (4) · 153
DOI: 10.13104/imri.2024.0009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Magnetic Resonance Imaging, 2024. Verfasst von Soham S More und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Engineering and Applied Sciences, and Jacobs School of Medicine and Biomedical Sciences, State Univer…. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 175 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIBIB NIH HHS.
Abstract (Originalsprache)
Ultrashort echo time (UTE) and zero echo time (ZTE) imaging sequences have been developed to detect short T2 relaxation signals emanating from regions or tissues that conventional magnetic resonance imaging (MRI) methods fail to capture. Owing to the high dipole-dipole interactions in solid and semisolid tissues, the signal decay occurs very rapidly, typically in less than 1 ms. The echo time generated by conventional imaging methods is insufficiently short, resulting in void signals from these short-T2 species. The application of UTE and ZTE techniques enables the imaging of solid and semi-solid tissues, making the conventionally invisible visible, which can significantly impact clinical imaging. High- and ultra-high-field-strength (UHF) MRI offers a critical advantage in enhancing the sensitivity and specificity of MRI. When combined with UTE and ZTE sequences, it enables the recovery of signals from void areas and markedly improves signal quality. To bolster this approach and further validate the technique, while addressing its limitations, extensive efforts have been made to collect supplementary data using various research tools. Studies demonstrate that integrating UTE and ZTE sequences with advanced high and ultra-high field imaging techniques-particularly innovative developments in transmit/receive hardware, software, and novel trajectory approaches-plays a pivotal role in enhancing the clarity and accuracy of MRI for musculoskeletal, neural, lung, and dental applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, School of Engineering and Applied Sciences, and Jacobs School of Medicine and Biomedical Sciences, State University of New York at Buffalo, Buffalo, NY, USA.
- Department of Electrical Engineering, School of Engineering and Applied Sciences, State University of New York at Buffalo, Buffalo, NY, USA.
ORCID-Profile: Soham S More, Xiaoliang Zhang
Förderung
- NIBIB NIH HHS
Zitieren
APA
More, S. S., & Zhang, X. (2024). Ultrashort Echo Time and Zero Echo Time MRI and Their Applications at High Magnetic Fields: A Literature Survey. Investigative Magnetic Resonance Imaging, 28(4), 153. https://doi.org/10.13104/imri.2024.0009
Vancouver
More SS, Zhang X. Ultrashort Echo Time and Zero Echo Time MRI and Their Applications at High Magnetic Fields: A Literature Survey. Investigative Magnetic Resonance Imaging. 2024;28(4):153. doi:10.13104/imri.2024.0009
BibTeX
@article{More2024,
author = {More, Soham S and Zhang, Xiaoliang},
title = {Ultrashort Echo Time and Zero Echo Time MRI and Their Applications at High Magnetic Fields: A Literature Survey},
journal = {Investigative Magnetic Resonance Imaging},
year = {2024},
volume = {28},
number = {4},
pages = {153},
doi = {10.13104/imri.2024.0009}
}