Kurz gefasst

Übersichtsarbeit in der Zeitschrift International Journal of Occupational Medicine and Environmental Health, 2025. Verfasst von Małgorzata Pawlaczyk-Łuszczyńska und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nofer Institute of Occupational Medicine, Łódź, Poland (Department of Vibroacoustic Hazards). Hauptthemen laut MEDLINE: Wind, Noise, Environmental Exposure, Power Plants. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The study focuses on setting outdoor exposure limits for wind turbine infrasound, as most countries currently have no specific limits for this type of noise.A review of the literature on the effects of wind turbine infrasound and the methods used worldwide to measure and assess environmental exposure to infrasound formed the basis for setting limits.According to the literature, human tolerance to infrasound is defined by the hearing threshold, which is not yet standardized.Therefore, a G96 curve (corresponding to tones with the G-weighted sound pressure level (SPL) equal to 96 dB) was used to determine the mean hearing threshold in the 1-20 Hz frequency range.Infrasound that cannot be heard (or felt) is not annoying and does not cause other adverse health effects.The infrasound levels measured around wind farms are well below the hearing threshold.Few countries have set limits for infrasound in either outdoor or indoor environments.The study proposes the G-weighted equivalent SPL as the basis for assessing exposure to infrasound from wind turbines.It also specifies preliminary short-term indices (i.e., G-weighted equivalent SPLs for daytime [L Geq, D ] and nighttime [L Geq, N ]) and long-term indices (i.e., averaged G-weighted day-evening-night infrasound level [L DEN(G) ] and G-weighted night infrasound level [L N(G) ]).In order to avoid annoyance and other possible harmful effects, regardless of land use, 90 dB was provisionally adopted as an acceptable value for L Geq, D and L DEN(G) , and 85 dB for L Geq, N and L N(G) .The study highlights the importance of considering specific exposure limits for wind turbine infrasound to ensure the well-being and comfort of people living near wind turbines.Int J Occup Med Environ Health.2025;38(1):3-17

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WindNoiseEnvironmental ExposurePower PlantsHumansAuditory Threshold

Stichwörter der Autor:innen

annoyanceenvironmental exposurehearing thresholdinfrasoundlimit valueswind turbines

Autor:innen und Institutionen

  • Nofer Institute of Occupational Medicine, Łódź, Poland (Department of Vibroacoustic Hazards).
  • AGH University of Science and Technology, Kraków, Poland (Faculty of Mechanical Engineering and Robotics, Department of Mechanics and Vibroacoustics).

Zitieren

APA

Pawlaczyk-Łuszczyńska, M., Wszołek, T., Dudarewicz, A., & Małecki, P. (2025). Should limit values be set for infrasound caused by wind turbines?. International Journal of Occupational Medicine and Environmental Health. https://doi.org/10.13075/ijomeh.1896.02422

Vancouver

Pawlaczyk-Łuszczyńska M, Wszołek T, Dudarewicz A, Małecki P. Should limit values be set for infrasound caused by wind turbines?. International Journal of Occupational Medicine and Environmental Health. 2025. doi:10.13075/ijomeh.1896.02422

BibTeX
@article{Pawlaczykuszczyska2025,
  author = {Pawlaczyk-Łuszczyńska, Małgorzata and Wszołek, Tadeusz and Dudarewicz, Adam and Małecki, Paweł},
  title = {Should limit values be set for infrasound caused by wind turbines?},
  journal = {International Journal of Occupational Medicine and Environmental Health},
  year = {2025},
  doi = {10.13075/ijomeh.1896.02422}
}
Kostenlos starten →