Comparing Passive Wick Lysimeter Against Soil Water Balance and Simulation Models in High and Perched Water Tables and Coarse Sandy Soils
Journal of Natural Resources and Agricultural Ecosystems · 2025
DOI: 10.13031/jnrae.16188 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Natural Resources and Agricultural Ecosystems, 2025. Verfasst von Bibek Acharya und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
Highlights Passive wick lysimeter performance was tested against soil water balance and simulation models under high and perched water table conditions. Passive wick lysimeters overestimated deep drainage as compared to soil water balance and simulation models. Lysimeter data inflated NO3-N leachate estimates, questioning the reliability in similar field conditions. The out-row placed lysimeters recorded higher drainage volumes than in-row placed. Abstract. Understanding soil water and nutrient dynamics is pivotal for agricultural and environmental research, particularly the accurate measurement of nutrient leaching. This study critically compares the performance of passive-wick drainage lysimeters to the soil water balance approach and simulation models such as DSSAT (Decision Support System for Agrotechnology Transfer) and HYDRUS-1D (1-dimensional) in estimating deep drainage and nitrate-nitrogen (NO 3 -N) leaching under field conditions marked by high and perched water tables and coarse sandy soils. The study was conducted at the North Florida Research and Education Center, Live Oak, FL, over four years (2019–2022). Forty passive-wick drainage lysimeters, with 25 in-row and 15 out-row placements, were installed 61 cm below the soil surface to record deep drainage measurements. The results showed lysimeters exhibited poor correlation (R 2 = 0.04) with soil water balance estimates during the crop growing season, alongside a Root Mean Square Error (RMSE) of 7.9 liters, indicating substantial measurement discrepancies. The average deep percolation from the lysimeter was 2221 mm (SD = 1490 mm), which was 841% higher than the soil water balance method, 741% higher than the DSSAT simulated deep drainage, and 774% higher than the HYDRUS-1D simulation. Keywords: Deep percolation, Drainage lysimeter, DSSAT, HYDRUS-1D, Nitrate leaching.
Zitieren
APA
Acharya, B., Sharma, V., Barrett, C., Dukes, M. D., & Zotarelli, L. (2025). Comparing Passive Wick Lysimeter Against Soil Water Balance and Simulation Models in High and Perched Water Tables and Coarse Sandy Soils. Journal of Natural Resources and Agricultural Ecosystems. https://doi.org/10.13031/jnrae.16188
Vancouver
Acharya B, Sharma V, Barrett C, Dukes MD, Zotarelli L. Comparing Passive Wick Lysimeter Against Soil Water Balance and Simulation Models in High and Perched Water Tables and Coarse Sandy Soils. Journal of Natural Resources and Agricultural Ecosystems. 2025. doi:10.13031/jnrae.16188
BibTeX
@article{Acharya2025,
author = {Acharya, Bibek and Sharma, Vivek and Barrett, Charles and Dukes, Michael D. and Zotarelli, Lincoln},
title = {Comparing Passive Wick Lysimeter Against Soil Water Balance and Simulation Models in High and Perched Water Tables and Coarse Sandy Soils},
journal = {Journal of Natural Resources and Agricultural Ecosystems},
year = {2025},
doi = {10.13031/jnrae.16188}
}
EUVIMED