Accuracy of New Water Meters Used to Monitor Water Usage in Commercial Poultry and Livestock Systems

Jeremiah D. Davis, Savannah L. Webb, Kelly G. Griggs, Jesse C. Campbell, Carson M. Edge, Joseph L. Purswell

Applied Engineering in Agriculture · 2026 · 42 (4) · 409-418

DOI: 10.13031/aea.16696 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Engineering in Agriculture, 2026. Verfasst von Jeremiah D. Davis und 5 weiteren Autor:innen. Gefördert von: USDA.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Highlights This was the first study to verify the accuracy of water meters used in poultry and livestock systems. For the 50 mechanical water meters tested, 96% were within manufacturer-specified errors. Excluding one manufacturer, 95% of the 40 ultrasonic meters tested were within manufacturer-specified errors. Most brands had < 2% absolute error across all flows under controlled test conditions. Abstract. Water usage, commonly stated as water consumption, is a parameter monitored across poultry and livestock production systems. Accurate measurements are needed to monitor health and disease, nutrition levels, and thermal homeostasis. Accuracy testing information is highly variable or missing across water meter brands. The objective of this study was to determine the accuracy of new water meters used in commercial poultry and livestock production systems. Eleven meter-treatments were created from five brands (Arad, BarnTools, Carlon, Dwyer, and Zaxe), three meter types (multijet, oscillating piston, and ultrasonic), and three sizes [16 × 20, 20, and 25 mm (5/8 × 3/4, 3/4, and 1 in.)]. A sample size of ten meters was tested for each meter treatment. Descriptive statistics were used to evaluate the number of meters in each treatment that passed three categories of maximum permissible error (MPE) for the maximum, intermediate, and minimum flow rates prescribed for the type and size of each meter. Of the 50 meters tested, 96% of the mechanical meters passed the manufacturer-specified MPE for all flow rates. The mean absolute error for all mechanical meter treatments was better than 1.37% for all flow rates. The multijet meters performed similarly across meter sizes. Excluding one manufacturer, 95% of the 40 ultrasonic meters tested passed the manufacturer-specified MPE for all flow rates. The mean absolute error for the ultrasonic meter treatments was better than 1.58% for all flow rates. The mean absolute error for the excluded brand was better than 5.98% for all flow rates. Most brands performed well across meter sizes and were within their manufacturer-reported accuracy under controlled test conditions. Keywords: Accuracy, Multijet, Positive displacement, Ultrasonic, Water meter.

Förderung

  • USDA

Zitieren

APA

Davis, J. D., Webb, S. L., Griggs, K. G., Campbell, J. C., Edge, C. M., & Purswell, J. L. (2026). Accuracy of New Water Meters Used to Monitor Water Usage in Commercial Poultry and Livestock Systems. Applied Engineering in Agriculture, 42(4), 409-418. https://doi.org/10.13031/aea.16696

Vancouver

Davis JD, Webb SL, Griggs KG, Campbell JC, Edge CM, Purswell JL. Accuracy of New Water Meters Used to Monitor Water Usage in Commercial Poultry and Livestock Systems. Applied Engineering in Agriculture. 2026;42(4):409-418. doi:10.13031/aea.16696

BibTeX
@article{Davis2026,
  author = {Davis, Jeremiah D. and Webb, Savannah L. and Griggs, Kelly G. and Campbell, Jesse C. and Edge, Carson M. and Purswell, Joseph L.},
  title = {Accuracy of New Water Meters Used to Monitor Water Usage in Commercial Poultry and Livestock Systems},
  journal = {Applied Engineering in Agriculture},
  year = {2026},
  volume = {42},
  number = {4},
  pages = {409--418},
  doi = {10.13031/aea.16696}
}
Kostenlos starten →