Wearable inertial sensors for clinical gait analysis in Parkinson’s disease: a test-retest reliability study

Thanakorn Angkurasiripaiboon, Chernkhuan Stonsaovapak, Maria Justine, Akkradate Siriphorn

Journal of Associated Medical Sciences · 04.09.2025 · 58 (3) · 354-360

DOI: 10.12982/jams.2025.107 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Associated Medical Sciences, online erschienen am 04.09.2025. Verfasst von Thanakorn Angkurasiripaiboon und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Parkinson’s disease (PD) is a neurodegenerative disorder that significantly affects gait parameters. Accurate and reliable gait assessment tools are essential for monitoring disease progression and treatment efficacy. The G-Walk®,a wearable inertial measurement device, offers a convenient and portable solution for evaluating spatiotemporal gait parameters, but its reliability in individuals with moderate-stage PD remains underexplored.

Objectives

This study aimed to evaluate the test-retest reliability of the G-Walk® sensor system in assessing gait parameters in individuals with moderate-stage PD. Materials and methods: Thirteen participants with idiopathic PD completed two walking trials on a 14-meter pathway, conducted 3 to 7 days apart. Gait parameters, including stride length, cadence, gait velocity, and limb support times, were recorded using the G-Walk® system. Intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated.

Results

The G-Walk® system demonstrated excellent reliability for stride length (ICC=0.979), cadence (ICC=0.958), and gait velocity (ICC=0.997). Moderate reliability was observed for single limb support (ICC=0.699) and double limb support times (ICC=0.656). SEM and MDC values further supported the precision of the system for clinical applications.

Conclusion

The G-Walk® sensor system is a reliable tool for assessing gait parameters in individuals with moderate-stage PD, particularly for stride length, cadence, and gait velocity. Its portability and ease of use make it suitable for clinical settings to track disease progression and evaluate interventions.

Zitieren

APA

Angkurasiripaiboon, T., Stonsaovapak, C., Justine, M., & Siriphorn, A. (2025). Wearable inertial sensors for clinical gait analysis in Parkinson’s disease: a test-retest reliability study. Journal of Associated Medical Sciences, 58(3), 354-360. https://doi.org/10.12982/jams.2025.107

Vancouver

Angkurasiripaiboon T, Stonsaovapak C, Justine M, Siriphorn A. Wearable inertial sensors for clinical gait analysis in Parkinson’s disease: a test-retest reliability study. Journal of Associated Medical Sciences. 2025;58(3):354-360. doi:10.12982/jams.2025.107

BibTeX
@article{Angkurasiripaiboon2025,
  author = {Angkurasiripaiboon, Thanakorn and Stonsaovapak, Chernkhuan and Justine, Maria and Siriphorn, Akkradate},
  title = {Wearable inertial sensors for clinical gait analysis in Parkinson’s disease: a test-retest reliability study},
  journal = {Journal of Associated Medical Sciences},
  year = {2025},
  volume = {58},
  number = {3},
  pages = {354--360},
  doi = {10.12982/jams.2025.107}
}
Kostenlos starten →