EUVIMEDEUVIMED entdecken
Crossref

Quantifying Scaling Aerosol Distribution Using ImageJ and Fluorescein Visualization: Effects of Operator and Tooth Location

Na-Young Lee, Han-Na Kim

Korean Journal of Clinical Dental Hygiene · 30.06.2026 · 14 (2) · 89-98

DOI: 10.12972/kjcdh.2026.14.2.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Korean Journal of Clinical Dental Hygiene, online erschienen am 30.06.2026. Verfasst von Na-Young Lee und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To quantify aerosol distribution patterns during ultrasonic scaling using a fluorescein visualization technique and ImageJ, and to identify high-risk conditions and establish evidencebased infection control protocols by analyzing contamination areas based on operator position and target tooth site.

Methods

A 1.0% sodium fluorescein solution was used as a coolant during scaling on a manikin. Variables included operator positions(7, 10:30, and 12 o’clock) and tooth areas. Images of aerosols visualized under ultraviolet light were captured and quantitatively analyzed for area ratios(%) using ImageJ software.

Results

Aerosol distribution varied significantly by operator position. The 12 o'clock position during anterior scaling had the highest contamination(17.17±3.00% vertical; 13.18±1.30% horizontal), with fan-shaped diffusion towards the face and chest of the operator. Conversely, the 10:30 position had the lowest contamination(0.42±0.39% vertical) due to the shielding effect of the buccal mucosa. Vertical imaging consistently had higher contamination ratios than horizontal imaging at all positions.

Conclusions

The spread of invisible aerosols were objectively quantified using fluorescence visualization. The findings highlight that the 12 o'clock position is highly vulnerable to contamination, providing critical data for optimizing operator positioning, personal protective equipment guidelines, and clinical infection control strategies.

Zitieren

APA

Lee, N., & Kim, H. (2026). Quantifying Scaling Aerosol Distribution Using ImageJ and Fluorescein Visualization: Effects of Operator and Tooth Location. Korean Journal of Clinical Dental Hygiene, 14(2), 89-98. https://doi.org/10.12972/kjcdh.2026.14.2.2

Vancouver

Lee N, Kim H. Quantifying Scaling Aerosol Distribution Using ImageJ and Fluorescein Visualization: Effects of Operator and Tooth Location. Korean Journal of Clinical Dental Hygiene. 2026;14(2):89-98. doi:10.12972/kjcdh.2026.14.2.2

BibTeX
@article{Lee2026,
  author = {Lee, Na-Young and Kim, Han-Na},
  title = {Quantifying Scaling Aerosol Distribution Using ImageJ and Fluorescein Visualization: Effects of Operator and Tooth Location},
  journal = {Korean Journal of Clinical Dental Hygiene},
  year = {2026},
  volume = {14},
  number = {2},
  pages = {89--98},
  doi = {10.12972/kjcdh.2026.14.2.2}
}
Kostenlos starten →