Application safety of airway devices by German paramedics
International Paramedic Practice · 02.05.2026 · 16 (1) · 22-30
DOI: 10.12968/ippr.2026.0007 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Paramedic Practice, erschienen am 02.05.2026. Verfasst von Andreas Behrnd und 4 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben.
Abstract (Originalsprache)
Introduction
There is debate about which airway devices are best used by German paramedics – particularly extraglottic airway devices (EGA) – but the perceived application safety of the user has not been considered.
Method
In July and August 2023, an online questionnaire developed by the authors was distributed among German paramedics and results were analysed descriptively. Differences between supplementary-trained (ST) and fully trained (FT) paramedics were determined using the Welch test. Factors for developing application safety when using laryngeal tubes (LT) and laryngeal masks (LMA) were analysed using logistic regression.
Results
780 data records were included. Participants have 13.6 years of professional experience (SD 9.1) and 33.0% have completed full-time training. Oropharyngeal tubes and nasopharyngeal tubes were used most frequently in the last 12 months. ST performed significantly better than FT in terms of self-perceived application safety of the use of LT, conventional (cETI) and video-assisted endotracheal intubation (vETI), puncture cricothyrotomy (PC), and overall self-perceived safety. In the logistic regression, years of professional experience ( p =0.003; OR 0.95), ST ( p
Zitieren
APA
Behrnd, A., Grönheim, H., Kerckhoff, A., Möckel, L., & Hofmann, T. (2026). Application safety of airway devices by German paramedics. International Paramedic Practice, 16(1), 22-30. https://doi.org/10.12968/ippr.2026.0007
Vancouver
Behrnd A, Grönheim H, Kerckhoff A, Möckel L, Hofmann T. Application safety of airway devices by German paramedics. International Paramedic Practice. 2026;16(1):22-30. doi:10.12968/ippr.2026.0007
BibTeX
@article{Behrnd2026,
author = {Behrnd, Andreas and Grönheim, Hanna and Kerckhoff, Annette and Möckel, Luis and Hofmann, Thomas},
title = {Application safety of airway devices by German paramedics},
journal = {International Paramedic Practice},
year = {2026},
volume = {16},
number = {1},
pages = {22--30},
doi = {10.12968/ippr.2026.0007}
}