EUVIMEDEUVIMED entdecken
Crossref

Application safety of airway devices by German paramedics

Andreas Behrnd, Hanna Grönheim, Annette Kerckhoff, Luis Möckel, Thomas Hofmann

International Paramedic Practice · 02.05.2026 · 16 (1) · 22-30

DOI: 10.12968/ippr.2026.0007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Paramedic Practice, erschienen am 02.05.2026. Verfasst von Andreas Behrnd und 4 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

There is debate about which airway devices are best used by German paramedics – particularly extraglottic airway devices (EGA) – but the perceived application safety of the user has not been considered.

Method

In July and August 2023, an online questionnaire developed by the authors was distributed among German paramedics and results were analysed descriptively. Differences between supplementary-trained (ST) and fully trained (FT) paramedics were determined using the Welch test. Factors for developing application safety when using laryngeal tubes (LT) and laryngeal masks (LMA) were analysed using logistic regression.

Results

780 data records were included. Participants have 13.6 years of professional experience (SD 9.1) and 33.0% have completed full-time training. Oropharyngeal tubes and nasopharyngeal tubes were used most frequently in the last 12 months. ST performed significantly better than FT in terms of self-perceived application safety of the use of LT, conventional (cETI) and video-assisted endotracheal intubation (vETI), puncture cricothyrotomy (PC), and overall self-perceived safety. In the logistic regression, years of professional experience ( p =0.003; OR 0.95), ST ( p

Zitieren

APA

Behrnd, A., Grönheim, H., Kerckhoff, A., Möckel, L., & Hofmann, T. (2026). Application safety of airway devices by German paramedics. International Paramedic Practice, 16(1), 22-30. https://doi.org/10.12968/ippr.2026.0007

Vancouver

Behrnd A, Grönheim H, Kerckhoff A, Möckel L, Hofmann T. Application safety of airway devices by German paramedics. International Paramedic Practice. 2026;16(1):22-30. doi:10.12968/ippr.2026.0007

BibTeX
@article{Behrnd2026,
  author = {Behrnd, Andreas and Grönheim, Hanna and Kerckhoff, Annette and Möckel, Luis and Hofmann, Thomas},
  title = {Application safety of airway devices by German paramedics},
  journal = {International Paramedic Practice},
  year = {2026},
  volume = {16},
  number = {1},
  pages = {22--30},
  doi = {10.12968/ippr.2026.0007}
}