EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Analysis of Marginal Adaptation for Zirconia Monolith Crowns Fabricated using Conventional Impression Versus Digital Impression Techniques

Komal Shah, Mukesh Kumar Goyal*, Geeta Paul, Isha Saxena, Madhav M, Shreysha S, Nidhi Shree, Bajaj Amitkumar Shamlal

ENVIRO Dental Journal · 11.06.2026 · 1 (08) · 58

DOI: 10.12944/edj.08.0108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ENVIRO Dental Journal, online erschienen am 10.06.2026. Verfasst von Komal Shah und 7 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This In- vitro comparative studyaimed to evaluate and compare the marginal fit of full-contour monolithic zirconia crowns fabricated using conventional and digital impression techniques, as marginal adaptation is a key factor influencing the biological success and longevity of fixed dental restorations. Poor marginal fit can result in plaque accumulation, gingival inflammation, secondary caries, and eventual failure of the prosthesis. Fifteen samples of monolithic zirconia crowns were fabricated in each of three groups resulting in total sample size of 45 (n=45).Group 1 utilized the conventional polyvinyl siloxane impression technique (3M ESPE/Dentsply, USA) with a die model (Neelkanth, India), Group 2 employed digital impressions obtained from Digital Scanner-A (UPCERA, China) with a 3D-printed resin model, and Group 3 used digital impressions from Digital Scanner-B(Medit i600, South Korea) with a 3D-printed resin model. All crowns were fabricated using a standardized CAD/CAM workflow, andMarginal discrepancy was evaluated using a stereomicroscope at 45× magnification and analyzed using image analysis software. Statistical analysis was performed using one-way ANOVA followed by post hoc testing. The results showed that the conventional technique exhibited the highest marginal discrepancy (77–84 µm), whereas both digital techniques demonstrated significantly lower discrepancies (41–47 µm) (p < 0.005), with no statistically significant difference between the two digital scanners. Within the limitations of this In- vitro study, digital impression techniques demonstrated superior marginal fit compared to the conventional impression technique.

Zitieren

APA

Shah, K., Goyal*, M. K., Paul, G., Saxena, I., M, M., S, S., Shree, N., & Shamlal, B. A. (2026). Comparative Analysis of Marginal Adaptation for Zirconia Monolith Crowns Fabricated using Conventional Impression Versus Digital Impression Techniques. ENVIRO Dental Journal, 1(08), 58. https://doi.org/10.12944/edj.08.0108

Vancouver

Shah K, Goyal* MK, Paul G, Saxena I, M M, S S, et al. Comparative Analysis of Marginal Adaptation for Zirconia Monolith Crowns Fabricated using Conventional Impression Versus Digital Impression Techniques. ENVIRO Dental Journal. 2026;1(08):58. doi:10.12944/edj.08.0108

BibTeX
@article{Shah2026,
  author = {Shah, Komal and Goyal*, Mukesh Kumar and Paul, Geeta and Saxena, Isha and M, Madhav and S, Shreysha and Shree, Nidhi and Shamlal, Bajaj Amitkumar},
  title = {Comparative Analysis of Marginal Adaptation for Zirconia Monolith Crowns Fabricated using Conventional Impression Versus Digital Impression Techniques},
  journal = {ENVIRO Dental Journal},
  year = {2026},
  volume = {1},
  number = {08},
  pages = {58},
  doi = {10.12944/edj.08.0108}
}
Kostenlos starten →