EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of specific IgE detection by immunoblotting and fluorescence enzyme assay with in vivo skin prick test

Jongkonnee Wongpiyabovorn, Narissara Suratannon, Sadudee Boonmee, Pantipa Chatchatee

Asian Pacific Journal of Allergy and Immunology · 2018

DOI: 10.12932/ap-270217-0035 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Asian Pacific Journal of Allergy and Immunology, 2017. Verfasst von Jongkonnee Wongpiyabovorn und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center of Excellence in Immunology and Immune Mediated Diseases, Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok, …. Die Arbeit wurde bisher 10-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Diagnostic tools to identify allergens that cause allergic symptom is important part in the care of allergic patients. Detection of causative allergen can be performed by in vivo skin prick test (SPT) or in vitro tests for detection serum specific immunoglobulin E (sIgE). The common methods used are fluorescent enzyme assay and immunoblotting assay. OBJECTIVE: We aim to evaluate performance of the two sIgE determination systems, immunoblotting assay (Euroline) and fluorescent enzyme assay (ImmunoCAP) in comparison with SPT. METHODS: Two hundred and two participants with allergic diseases were enrolled. Sensitization to common allergens was identified using skin prick test and serum specific IgE assays with Euroline and ImmunoCAP. Both systems provide the result in the same unit and the same cut-off value (0.35 kUA/L). The specific IgE levels of 4 aeroallergens, 6 food allergens and 3 food allergen components were analyzed to evaluate the performance of both sIgE assays with SPT. RESULTS: When compared with the result of SPT, ImmunoCAP has 63.9-93.2% agreement and Euroline has 68.4-86.2% agreement for allergen detection. Both sIgE assays have significant correlation in measuring sIgE of almost all allergens (r=0.626-0.901, p< 0.001) except for dog. For food allergen components, both sIgE tests have outstanding correlation and agreement (r=0.816-0.952, p< 0.001; agreement =87.0-92.9%, respectively). The receiver-operating characteristic curve analysis indicated slight discrepancy of both sIgE assays. CONCLUSIONS: Both sIgE determination systems demonstrate fair to good performance when compared to SPT depending on type of allergens. The two sIgE determination systems had favorable correlation and agreement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdolescentAdultChildChild, PreschoolFemaleFluorescent Antibody TechniqueHumansHypersensitivityImmunoblottingImmunoglobulin EInfantMaleMiddle AgedSensitivity and SpecificitySkin TestsYoung Adult

Substanzen

Immunoglobulin E

Autor:innen und Institutionen

  • Center of Excellence in Immunology and Immune Mediated Diseases, Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Division of Allergy and Immunology, Department of Pediatrics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.

Zitieren

APA

Wongpiyabovorn, J., Suratannon, N., Boonmee, S., & Chatchatee, P. (2018). Comparison of specific IgE detection by immunoblotting and fluorescence enzyme assay with in vivo skin prick test. Asian Pacific Journal of Allergy and Immunology. https://doi.org/10.12932/ap-270217-0035

Vancouver

Wongpiyabovorn J, Suratannon N, Boonmee S, Chatchatee P. Comparison of specific IgE detection by immunoblotting and fluorescence enzyme assay with in vivo skin prick test. Asian Pacific Journal of Allergy and Immunology. 2018. doi:10.12932/ap-270217-0035

BibTeX
@article{Wongpiyabovorn2018,
  author = {Wongpiyabovorn, Jongkonnee and Suratannon, Narissara and Boonmee, Sadudee and Chatchatee, Pantipa},
  title = {Comparison of specific IgE detection by immunoblotting and fluorescence enzyme assay with in vivo skin prick test},
  journal = {Asian Pacific Journal of Allergy and Immunology},
  year = {2018},
  doi = {10.12932/ap-270217-0035}
}
Kostenlos starten →