Fachartikel in der Zeitschrift Journal of Veterinary Medical Science, 2024. Verfasst von Shanshan Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Changchun Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Changchun, China. Hauptthemen laut MEDLINE: Distemper Virus, Canine, Distemper, Sensitivity and Specificity, Nucleic Acid Amplification Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
In the present study, recombinase polymerase amplification (RPA) was combined with the colloidal gold lateral flow dipstick (LFD) method to establish a new, stable, and efficient assay for the detection of canine distemper virus (CDV). We designed a set of specific primers labeled with biotin and a specific probe labeled with dSpacer and C3 spacer, according to the conserved region in the N-terminal gene sequence of CDV. The reaction conditions and systems were then optimized, and the sensitivity and specificity were analyzed for potential clinical application. The results showed that the RPA-LFD assay for CDV detection was successfully established. We also found that the temperature in a closed fist (35°C) is optimal for the RPA reaction. The optimal ratio of primer to probe was 2:1. The minimum detection limit of the RPA-LFD assay was 1 × 101 the median tissue culture infective dose (TCID50)/mL. Using this assay with samples from experimentally infected dogs, CDV was detected in nasal secretions, eye secretions, and blood on the fourth day post infection. In summary, this novel RPA-LFD assay for CDV detection is simple to use, and preliminary findings indicate its high specificity and sensitivity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Changchun Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Changchun, China.
Zitieren
APA
Zhang, S., Wang, C., Meng, K., & Liu, J. (2024). Recombinase polymerase amplification-lateral flow dipstick (RPA-LFD) designed for rapid detection of canine distemper virus. Journal of Veterinary Medical Science, 86(5), 584-591. https://doi.org/10.1292/jvms.23-0389
Vancouver
Zhang S, Wang C, Meng K, Liu J. Recombinase polymerase amplification-lateral flow dipstick (RPA-LFD) designed for rapid detection of canine distemper virus. Journal of Veterinary Medical Science. 2024;86(5):584-591. doi:10.1292/jvms.23-0389
BibTeX
@article{Zhang2024,
author = {Zhang, Shanshan and Wang, Chengyu and Meng, Keyin and Liu, Jun},
title = {Recombinase polymerase amplification-lateral flow dipstick (RPA-LFD) designed for rapid detection of canine distemper virus},
journal = {Journal of Veterinary Medical Science},
year = {2024},
volume = {86},
number = {5},
pages = {584--591},
doi = {10.1292/jvms.23-0389}
}
EUVIMED