Time-domain analysis of reactive power compensation for voltage stability in wind-integrated power networks
Ecological Engineering & Environmental Technology · 15.08.2026 · 27 (9) · 223-239
DOI: 10.12912/27197050/226295 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ecological Engineering & Environmental Technology, online erschienen am 15.08.2026. Verfasst von Kadhim Hamzah Chalok und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This paper presents a time-domain simulation study of dynamic reactive power compensation for voltage stability in a wind-integrated power system. A 50 MW doubly-fed induction generator (DFIG) wind farm is connected at bus 9 of the IEEE 14-bus network, comparing two technologies: a Static Synchronous Compensator (STATCOM) with a PI voltage regulator and anti-windup, and a static VAR compensator (SVC) with a thyristor-controlled reactor and first-order lag dynamics. Bus voltages are computed via a full Newton-Raphson power-flow solver on the complete 14 × 14 admittance matrix. Wind speed is modelled using an AR (1) process calibrated to IEC 61400 Class B conditions. Simulations span seven mean wind speeds (3–18 m/s) at 30% penetration, plus a sensitiv - ity analysis across five penetration levels (10–50%) at rated speed. STATCOM reduces bus-9 voltage deviation from 2.79–2.97% to 0.61–0.80% (73–79% reduction); SVC achieves only 59–65% reduction with larger residual fluctuations. This advantage is confirmed by a Monte Carlo analysis (N = 15 independent AR(1) realisations per operating point), which shows STATCOM outperforming SVC at every tested wind speed with high statistical significance (p < 0.001, Wilcoxon signed-rank test), and reproduces on an independent, larger IEEE 30-bus net - work. Both compensators slightly increase network-wide reactive losses relative to the uncompensated case on the IEEE 14-bus network (STATCOM: +2.9 to +4.4%; SVC: +2.5 to +3.5%). Within the investigated simulation scenarios, both compensators maintained stable operation across all tested wind penetration levels (10–50%) on both networks.
Zitieren
APA
Chalok, K. H., & Kadhim, K. H. (2026). Time-domain analysis of reactive power compensation for voltage stability in wind-integrated power networks. Ecological Engineering & Environmental Technology, 27(9), 223-239. https://doi.org/10.12912/27197050/226295
Vancouver
Chalok KH, Kadhim KH. Time-domain analysis of reactive power compensation for voltage stability in wind-integrated power networks. Ecological Engineering & Environmental Technology. 2026;27(9):223-239. doi:10.12912/27197050/226295
BibTeX
@article{Chalok2026,
author = {Chalok, Kadhim Hamzah and Kadhim, Karrar Hameed},
title = {Time-domain analysis of reactive power compensation for voltage stability in wind-integrated power networks},
journal = {Ecological Engineering & Environmental Technology},
year = {2026},
volume = {27},
number = {9},
pages = {223--239},
doi = {10.12912/27197050/226295}
}
EUVIMED