EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wind-solar complementarity: A daily-resolution assessment for renewable energy planning in Iraq (2020–2024)

Muna H. Ahmed, Taghreed A. Abbas

Ecological Engineering & Environmental Technology · 01.07.2026 · 27 (7) · 343-361

DOI: 10.12912/27197050/223970 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ecological Engineering & Environmental Technology, online erschienen am 01.07.2026. Verfasst von Muna H. Ahmed und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the first daily-resolution assessment of solar attenuation mechanisms across Iraq’s climatic gradient using five years of ground-based observations (2020–2024) from the Iraqi Meteorological Organization and Seismology. Six novel analyses are applied to data from Basrah, Baghdad, Mosul, and Sulaymaniyah: extreme event characterisation, composite recovery curves, dust–rainfall separation via diffuse fraction validation, viable solar season length, rainfall intensity breakpoints, and daily Weibull wind fitting. Results reveal a pronounced north–south dichotomy: southern arid zones experience dust-dominated attenuation with rapid 1–2 day recovery, while northern Mediterranean zones face rainfall-driven suppression requiring 3–5 days storage autonomy. Diffuse fraction analysis confirms dust days elevate scattering to 0.48–0.56 (ΔDF = +0.27–0.31 vs. clear), mechanistically distinct from rain events (DF > 0.60). Wind–solar correlations are uniformly positive (r = +0.21 to +0.36, p < 0.001), refuting complementarity and confirming synchronous summer peaking via shamal circulation. Rainfall thresholds for 50% irradiance loss range from 6.8 mm/day (Basrah) to 9.2 mm/day (Mosul), directly informing battery autonomy sizing. A representative 10 kWh/day load requires 28.8 kWh storage in Basrah versus 71.9 kWh in northern cities. Daily Weibull fitting identifies Basrah as the only marginally viable wind site (92.8 W/ m²). These findings establish a daily-resolution design framework for renewable integration in arid climates, dem - onstrating that climate-zone-specific battery storage, not wind hybridization is critical for winter grid reliability.

Zitieren

APA

Ahmed, M. H., & Abbas, T. A. (2026). Wind-solar complementarity: A daily-resolution assessment for renewable energy planning in Iraq (2020–2024). Ecological Engineering & Environmental Technology, 27(7), 343-361. https://doi.org/10.12912/27197050/223970

Vancouver

Ahmed MH, Abbas TA. Wind-solar complementarity: A daily-resolution assessment for renewable energy planning in Iraq (2020–2024). Ecological Engineering & Environmental Technology. 2026;27(7):343-361. doi:10.12912/27197050/223970

BibTeX
@article{Ahmed2026,
  author = {Ahmed, Muna H. and Abbas, Taghreed A.},
  title = {Wind-solar complementarity: A daily-resolution assessment for renewable energy planning in Iraq (2020–2024)},
  journal = {Ecological Engineering & Environmental Technology},
  year = {2026},
  volume = {27},
  number = {7},
  pages = {343--361},
  doi = {10.12912/27197050/223970}
}
Kostenlos starten →