Normalising high-stakes innovation: insights from Hong Kong’s first intraoperative magnetic resonance imaging service
Hong Kong Medical Journal · 21.07.2026
DOI: 10.12809/hkmj2514258 ↗Kurz gefasst
Editorial in der Zeitschrift Hong Kong Medical Journal, online erschienen am 21.07.2026. Verfasst von C K M Lam und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesia and Operating Theatre Services, Tuen Mun Hospital, Hong Kong SAR, China. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BackgroundIntraoperative magnetic resonance imaging (IoMRI) represents a substantial advancement in neurosurgical precision, but it introduces serious safety challenges, particularly concerning ferromagnetic hazards.Recent global incidents underscore the gravity of these risks.In 2018 in India, 1 a patient fatality occurred when an oxygen cylinder, inadvertently introduced into the MRI suite, became a projectile during a routine scan; subsequent analysis revealed failures in prescreening protocols and zone enforcement.In 2023 in Brazil, 2 during IoMRI-guided brain tumour resection, a ferromagnetic aneurysm clip dislodged mid-scan, resulting in catastrophic haemorrhage attributed to mislabelling of the clip's magnetic resonance-conditional status.In 2025 in the United States, 3 a fatal incident involved a man being drawn into an MRI machine while wearing a heavy metal necklace.The American College of Radiology 4 reports that 70% of IoMRI adverse events involve ferromagnetic objects, whereas 80% arise from human factors, including inadequate training and communication failures.Against this backdrop, Hong Kong's first IoMRI service at Tuen Mun Hospital, launched in March 2025, confronted challenges within the constraints of a public healthcare system, balancing innovation with stringent safety requirements.Its developmentfrom early planning to service implementationwas framed not merely as a technical installation but as an organisational transformation, aiming to balance improved resection accuracy with the management of inherently high-stakes risks in a resource-conscious public healthcare setting.Adopting a two-room configuration, on one hand, enhances safety through double-door security and magnetic shielding; on the other hand, it facilitates modular scheduling of the scanner room for different purposes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anaesthesia and Operating Theatre Services, Tuen Mun Hospital, Hong Kong SAR, China.
- Department of Diagnostic Radiology, Tuen Mun Hospital, Hong Kong SAR, China.
- Department of Neurosurgery, Tuen Mun Hospital, Hong Kong SAR, China.
Zitieren
APA
Lam, C. K. M., Lee, P. Y. S., Ho, W. N., Wong, S. T., Cheng, B. C. P., & Wong, I. Y. C. (2026). Normalising high-stakes innovation: insights from Hong Kong’s first intraoperative magnetic resonance imaging service. Hong Kong Medical Journal. https://doi.org/10.12809/hkmj2514258
Vancouver
Lam CKM, Lee PYS, Ho WN, Wong ST, Cheng BCP, Wong IYC. Normalising high-stakes innovation: insights from Hong Kong’s first intraoperative magnetic resonance imaging service. Hong Kong Medical Journal. 2026. doi:10.12809/hkmj2514258
BibTeX
@article{Lam2026,
author = {Lam, C K M and Lee, P Y S and Ho, W N and Wong, S T and Cheng, B C P and Wong, I Y C},
title = {Normalising high-stakes innovation: insights from Hong Kong’s first intraoperative magnetic resonance imaging service},
journal = {Hong Kong Medical Journal},
year = {2026},
doi = {10.12809/hkmj2514258}
}
EUVIMED