Fachartikel in der Zeitschrift Hong Kong Medical Journal, 2025. Verfasst von C F Ng und 4 weiteren Autor:innen. Beteiligte Einrichtung: SH Ho Urology Centre, Department of Surgery, The Chinese University of Hong Kong, Hong Kong SAR, China. Hauptthemen laut MEDLINE: Prostatectomy, Robotic Surgical Procedures, Prostatic Neoplasms, Postoperative Complications. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This prospective clinical study evaluated the clinical safety and efficacy of the Sentire Surgical System (C1000), a locally developed robotic surgical platform, in performing radical prostatectomy in Hong Kong. METHODS: This was a single-centre, single-arm study. Adult patients with a clinical diagnosis of localised prostate cancer planned for surgical treatment were invited to participate. Surgery was performed using the Sentire C1000 system following the standard approach. The primary endpoints were the conversion rate and the incidence of perioperative complications within 30 days. Secondary outcomes, including perioperative, pathological, oncological, and functional outcomes at 1 month after surgery, were also assessed. RESULTS: From August 2022 to September 2023, 20 patients were recruited. All procedures were performed without conversion. There were no intraoperative complications related to the robotic device. Minor surgical complications (Grade I-II according to the Clavien-Dindo Classification) occurred in seven patients and were managed conservatively. The mean total operative time was 184.5 minutes (standard deviation=30.0). The median estimated blood loss was 175.0 mL (interquartile range [IQR]=100.0-275.0). The median length of hospital stay was 3.0 days (IQR=2.0-4.0). Seventeen patients achieved undetectable levels of prostate-specific antigen at 1 month after surgery. CONCLUSION: These initial results support the Sentire Surgical System (C1000), Hong Kong's first locally developed multidisciplinary robotic surgical platform, as a safe and effective option for radical prostatectomy, with clinical performance and outcomes comparable to existing robotic systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProstatectomyRobotic Surgical ProceduresProstatic NeoplasmsPostoperative ComplicationsHumansMaleMiddle AgedProspective StudiesAgedHong KongOperative TimeLength of StayTreatment Outcome

Stichwörter der Autor:innen

ProstatectomyProstatic neoplasmsRobotic surgical procedures

Autor:innen und Institutionen

  • SH Ho Urology Centre, Department of Surgery, The Chinese University of Hong Kong, Hong Kong SAR, China.

Zitieren

APA

Ng, C. F., Yee, C. H., Chiu, P. K. F., Tam, M. H. M., & Lai, F. P. T. (2025). Evaluation of the safety and efficacy of the Sentire Surgical System (C1000) for robot-assisted radical prostatectomy. Hong Kong Medical Journal. https://doi.org/10.12809/hkmj2412169

Vancouver

Ng CF, Yee CH, Chiu PKF, Tam MHM, Lai FPT. Evaluation of the safety and efficacy of the Sentire Surgical System (C1000) for robot-assisted radical prostatectomy. Hong Kong Medical Journal. 2025. doi:10.12809/hkmj2412169

BibTeX
@article{Ng2025,
  author = {Ng, C F and Yee, C H and Chiu, P K F and Tam, M H M and Lai, F P T},
  title = {Evaluation of the safety and efficacy of the Sentire Surgical System (C1000) for robot-assisted radical prostatectomy},
  journal = {Hong Kong Medical Journal},
  year = {2025},
  doi = {10.12809/hkmj2412169}
}
Kostenlos starten →