EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Development and evaluation of automated screening algorithms for pre-analytical errors in pharmacokinetic data: a simulation-based study

Minsub Shim iD, Jaegu Kang iD, Kyung-Sang Yu iD, Ki Young Huh iD

Translational and Clinical Pharmacology · 2026 · 34 (2) · 71

DOI: 10.12793/tcp.2026.34.e10 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational and Clinical Pharmacology, 2026. Verfasst von Minsub Shim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Pharmacology and Therapeutics, Seoul National University Hospital, Seoul National University College of Medicine, Seoul 03080,…. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pre-analytical errors such as sample mix-ups can compromise the integrity of pharmacokinetic (PK) data.We simulated vancomycin PK data and introduced two error types: intra-individual time point swap (TS) errors and inter-individual concentration swap (CS) errors.This study developed and validated two automated detection approaches-a run-test-based non-parametric method and a Mahalanobis distance-based method with leave-one-out cross-validation (LOOCV)-for identifying pre-analytical errors in PK datasets.Performance was evaluated using 12,500 simulated profiles comparing the two methods.The distance-based method demonstrated significantly higher error detection rate (79.7% vs. 59.6%, p < 0.001) and greater area under the receiver operating characteristic curve (0.856; 95% confidence interval [CI], 0.816-0.889vs. 0.574; 95% CI, 0.541-0.610)compared to the run-test, while maintaining reasonable specificity (76.4% vs. 84.0%).For TS errors, the distance-based method achieved higher recall (80.4% vs. 71.9%)and modestly higher F1-score (0.530 vs. 0.515).For CS errors, the distance-based method demonstrated superior precision (86.1% vs. 59.8%) with comparable F1-score (0.572 vs. 0.564).Detection was robust across alternative PopPK models, a structurally different drug (theophylline), training-set contamination (with the minimum covariance determinant estimator recommended for non-curated training), missing data (with sub-vector marginal handling), and samplingtime jitter.Overall, the distance-based method with LOOCV outperformed the conventional run-test across key performance metrics and can serve as a practical quality control tool for ensuring PK data integrity in clinical pharmacology research.

Schlagwörter

Stichwörter der Autor:innen

AlgorithmsMonte Carlo MethodPharmacokineticsQuality Control

Autor:innen und Institutionen

  • Department of Clinical Pharmacology and Therapeutics, Seoul National University Hospital, Seoul National University College of Medicine, Seoul 03080, Korea.

ORCID-Profile: Minsub Shim, Jaegu Kang, Kyung-Sang Yu, Ki Young Huh

Zitieren

APA

Shim, M., Kang, J., Yu, K. S., & Huh, K. Y. (2026). Development and evaluation of automated screening algorithms for pre-analytical errors in pharmacokinetic data: a simulation-based study. Translational and Clinical Pharmacology, 34(2), 71. https://doi.org/10.12793/tcp.2026.34.e10

Vancouver

Shim M, Kang J, Yu KS, Huh KY. Development and evaluation of automated screening algorithms for pre-analytical errors in pharmacokinetic data: a simulation-based study. Translational and Clinical Pharmacology. 2026;34(2):71. doi:10.12793/tcp.2026.34.e10

BibTeX
@article{Shim2026,
  author = {Shim, Minsub and Kang, Jaegu and Yu, Kyung-Sang and Huh, Ki Young},
  title = {Development and evaluation of automated screening algorithms for pre-analytical errors in pharmacokinetic data: a simulation-based study},
  journal = {Translational and Clinical Pharmacology},
  year = {2026},
  volume = {34},
  number = {2},
  pages = {71},
  doi = {10.12793/tcp.2026.34.e10}
}
Kostenlos starten →