EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review

Oliwia Gałczyńska, Zuzanna Zofia Cecot, Jarosław Józef Kucharski, Maciej Mariusz Lesiczka, Julia Weronika Duszejko, Filip Lenartowicz, Anna Maciaszczyk, Katarzyna Kuklińska, Alicja Martyna Lewczuk, Dawid Oskar Mazurek

Quality in Sport · 15.11.2026 · 79 · 76805

DOI: 10.12775/qs.2026.79.76805 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quality in Sport, online erschienen am 15.11.2026. Verfasst von Oliwia Gałczyńska und 9 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate resting blood pressure measurement in adults engaged in resistance training may be complicated by large upper-arm circumference and inadequate cuff fit. Evidence from general adult populations requires careful interpretation when applied to muscular arms.

Aim

To evaluate evidence on cuff selection and blood pressure measurement accuracy and assess its applicability to adults engaged in resistance training. Materials and Methods: This narrative review combined targeted Europe PMC searches restricted to PubMed records with supplementary publisher and reference-list searches. Twenty-five publications were assessed in full text. One additional study involving competitive bodybuilders was discussed separately using its indexed abstract. Findings were synthesized qualitatively, considering study design, cuff characteristics, reference methods and population applicability.

Results

Studies in general adult populations demonstrated that cuff size, geometry, positioning and device configuration can affect blood pressure readings. In a study of 193 competitive bodybuilders, the abstract reported that medium cuffs produced systolic readings averaging 8.2 mmHg higher than large cuffs in participants with arm circumference exceeding 33 cm. This represents between-cuff disagreement rather than established error against an independent reference; unavailable full text limited methodological appraisal. The reviewed evidence supports measuring arm circumference, assessing cuff fit and using validated device–cuff combinations. It does not establish a universally optimal cuff or a muscularity-specific correction factor.

Conclusions

Appropriate cuff selection is essential when interpreting blood pressure in resistance-trained adults. Findings from other populations support standardized measurement but require dedicated validation in muscular arms. Persistently elevated readings after technical correction warrant clinical evaluation.

Zitieren

APA

Gałczyńska, O., Cecot, Z. Z., Kucharski, J. J., Lesiczka, M. M., Duszejko, J. W., Lenartowicz, F., Maciaszczyk, A., Kuklińska, K., Lewczuk, A. M., & Mazurek, D. O. (2026). Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review. Quality in Sport, 79, 76805. https://doi.org/10.12775/qs.2026.79.76805

Vancouver

Gałczyńska O, Cecot ZZ, Kucharski JJ, Lesiczka MM, Duszejko JW, Lenartowicz F, et al. Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review. Quality in Sport. 2026;79:76805. doi:10.12775/qs.2026.79.76805

BibTeX
@article{Gaczyska2026,
  author = {Gałczyńska, Oliwia and Cecot, Zuzanna Zofia and Kucharski, Jarosław Józef and Lesiczka, Maciej Mariusz and Duszejko, Julia Weronika and Lenartowicz, Filip and Maciaszczyk, Anna and Kuklińska, Katarzyna and Lewczuk, Alicja Martyna and Mazurek, Dawid Oskar},
  title = {Cuff Selection and Blood Pressure Measurement Accuracy in Adults Engaged in Resistance Training A Narrative Review},
  journal = {Quality in Sport},
  year = {2026},
  volume = {79},
  pages = {76805},
  doi = {10.12775/qs.2026.79.76805}
}
Kostenlos starten →