EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Wrist-worn wearables for atrial fibrillation detection: diagnostic performance of PPG versus single-lead ECG – a review

Adrianna Dobrosielska, Iga Woźniakowska, Maja Zambrzycka, Aleksandra Misarko, Monika Jedwabnik, Stanisław Ścigała, Krzysztof Peszuk, Weronika Lech, Hoang Viet Krajewski, Bartosz Olszewski

Quality in Sport · 14.06.2026 · 58 · 72660

DOI: 10.12775/qs.2026.58.72660 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Quality in Sport, online erschienen am 14.06.2026. Verfasst von Adrianna Dobrosielska und 9 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and an important cause of stroke and reduced quality of life. Standard methods such as 12-lead electrocardiography and Holter monitoring cover only limited periods and are not ideal for repeated screening. Wrist-worn devices, including smartwatches and fitness bands, are now part of a healthy lifestyle and are widely used by athletes and physically active individuals. Many record photoplethysmography (PPG), single-lead electrocardiography (ECG), or both, but their diagnostic value in AF detection is still not fully established.

Aim

To compare the diagnostic performance of wrist-worn devices using PPG and single-lead ECG for AF detection in adults. Material and methods: A systematic PubMed search was performed using smartwatch- and AF-related terms. The search was limited to the last five years, English language, human studies, and free full-text articles. Of 44 records, 13 original studies were included after screening.

Results

In controlled cohorts with good signal quality, PPG-based algorithms usually showed sensitivity and specificity around 94–95% or higher. In real-world settings, especially in older post-stroke patients, sensitivity of irregular rhythm notifications was much lower, around one third, although specificity reached 100%. Single-lead ECG smartwatches and ambulatory ECG recorders usually achieved sensitivity and specificity above 90%. Physician interpretation of smartwatch ECG recordings improved diagnostic accuracy.

Conclusions

Both PPG- and ECG-based wrist-worn devices can detect AF with high accuracy in selected settings. In routine practice, ECG-based devices seem more reliable, while PPG results are more dependent on signal quality and algorithm design. Positive findings should still be confirmed by standard ECG.

Zitieren

APA

Dobrosielska, A., Woźniakowska, I., Zambrzycka, M., Misarko, A., Jedwabnik, M., Ścigała, S., Peszuk, K., Lech, W., Krajewski, H. V., & Olszewski, B. (2026). Wrist-worn wearables for atrial fibrillation detection: diagnostic performance of PPG versus single-lead ECG – a review. Quality in Sport, 58, 72660. https://doi.org/10.12775/qs.2026.58.72660

Vancouver

Dobrosielska A, Woźniakowska I, Zambrzycka M, Misarko A, Jedwabnik M, Ścigała S, et al. Wrist-worn wearables for atrial fibrillation detection: diagnostic performance of PPG versus single-lead ECG – a review. Quality in Sport. 2026;58:72660. doi:10.12775/qs.2026.58.72660

BibTeX
@article{Dobrosielska2026,
  author = {Dobrosielska, Adrianna and Woźniakowska, Iga and Zambrzycka, Maja and Misarko, Aleksandra and Jedwabnik, Monika and Ścigała, Stanisław and Peszuk, Krzysztof and Lech, Weronika and Krajewski, Hoang Viet and Olszewski, Bartosz},
  title = {Wrist-worn wearables for atrial fibrillation detection: diagnostic performance of PPG versus single-lead ECG – a review},
  journal = {Quality in Sport},
  year = {2026},
  volume = {58},
  pages = {72660},
  doi = {10.12775/qs.2026.58.72660}
}
Kostenlos starten →