EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Beyond Protocol Automation: A Sociotechnical Framework for Understanding and Measuring CT and MRI Acquisition Protocol Adherence in Resource-Constrained Healthcare Settings

Attah Kenneth Ifeanyi, Ogenyi Fabian Chukwudi

F1000Research · 10.11.2026 · 15 · 1877

DOI: 10.12688/f1000research.193568.1 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift F1000Research, online erschienen am 10.11.2026. Verfasst von Attah Kenneth Ifeanyi und 1 weiteren Autor:innen. Die Arbeit nennt 118 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Adherence to computed tomography (CT) and magnetic resonance imaging (MRI) acquisition protocols is essential for image quality, diagnostic reliability, and patient safety. However, adherence is influenced by technological, infrastructural, professional, and organisational factors, particularly in resource-constrained healthcare settings. Artificial intelligence (AI) may support protocol standardisation and quality assurance, but its effectiveness depends on implementation context.

Objective

To examine how technological, infrastructural, human, and organisational determinants influence CT and MRI acquisition protocol adherence and develop a framework linking failure mechanisms to measurable outcomes and corrective strategies. Review approach: This narrative review synthesises literature on AI-enabled imaging technologies, technical infrastructure, professional competence, workflow demands, and organisational governance across protocol selection, acquisition, and post-acquisition quality assurance. Synthesis and contribution The review conceptualises protocol adherence as a sociotechnical process and proposes a determinant-to-failure-to-measurement framework linking contextual constraints to protocol-selection errors, acquisition deviations, and quality-assurance failures. It identifies potential indicators, including protocol deviations, omitted sequences, repeat examinations attributable to acquisition errors, and image adequacy, alongside context-appropriate interventions such as staff training, standardised checklists, protocol audits, and AI-enabled monitoring.

Conclusion

Sustainable improvement requires alignment between technology, infrastructure, professional competence, and organisational governance. The proposed framework may guide quality improvement and future research, although its relationships require empirical validation.

Zitieren

APA

Ifeanyi, A. K., & Chukwudi, O. F. (2026). Beyond Protocol Automation: A Sociotechnical Framework for Understanding and Measuring CT and MRI Acquisition Protocol Adherence in Resource-Constrained Healthcare Settings. F1000Research, 15, 1877. https://doi.org/10.12688/f1000research.193568.1

Vancouver

Ifeanyi AK, Chukwudi OF. Beyond Protocol Automation: A Sociotechnical Framework for Understanding and Measuring CT and MRI Acquisition Protocol Adherence in Resource-Constrained Healthcare Settings. F1000Research. 2026;15:1877. doi:10.12688/f1000research.193568.1

BibTeX
@article{Ifeanyi2026,
  author = {Ifeanyi, Attah Kenneth and Chukwudi, Ogenyi Fabian},
  title = {Beyond Protocol Automation: A Sociotechnical Framework for Understanding and Measuring CT and MRI Acquisition Protocol Adherence in Resource-Constrained Healthcare Settings},
  journal = {F1000Research},
  year = {2026},
  volume = {15},
  pages = {1877},
  doi = {10.12688/f1000research.193568.1}
}
Kostenlos starten →