EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of the effect of two conventional and one herbal mouthwash on the modulus of elasticity of three orthodontic wires: an in vitro study.

Neharika Kapur, Ritesh Singla iD, Nishu Singla iD, Madhumitha Natarajan

F1000Research · 2025

DOI: 10.12688/f1000research.156706.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift F1000Research, 2025. Verfasst von Neharika Kapur und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics & Dentofacial Orthopaedics, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education, Manipal, Kar…. Hauptthemen laut MEDLINE: Mouthwashes, Orthodontic Wires, Elastic Modulus. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

During fixed appliance therapy, maintaining good oral hygiene is crucial; however, certain mouthwashes can negatively impact orthodontic treatment by altering the mechanical properties of archwires. The study investigated the impact of conventional mouthwashes on orthodontic archwires’ Modulus of Elasticity (MoE).

Methods

It was an in vitro study that tested MoE of stainless steel (SS), nickel-titanium (NiTi), and β-titanium (β-Ti) archwires after immersing them in chlorhexidine (CHX), sodium fluoride (NaF), and HiORA mouthwashes along with distilled water (control) for one minute daily over three months. The wires were then subjected to a three-point bending test to measure their flexural modulus of elasticity (MoE) while applying loading and unloading forces at 0.5, 1, 1.5, 2, and 2.5 mm deflections. Statistical analysis included two-way ANOVA and Tukey’s Post Hoc test at significant α≤0.05.

Results

NaF reduced MoE for SS (loading 172.99 ± 7.71 GPa, unloading 148.88 ± 14.65 GPa), NiTi (Loading: 48.42 ± 6.13 GPa, unloading 30.60 ± 4.29 GPa), β-Ti wires (unloading 79.51 ± 1.62 GPa) than Control (loading 185.35 ± 8.06 GPa, unloading 199.78 ± 9.49 GPa) with p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MouthwashesOrthodontic WiresElastic ModulusChlorhexidineTitaniumSodium FluorideMaterials TestingStainless SteelNickel

Stichwörter der Autor:innen

Beta titaniumHiORA.Modulus of Elasticity (MoE)MouthwashStainless steelchlorhexidineherbalnickel-titaniumorthodontics archwiressodium fluoridestiffness

Substanzen

MouthwashesChlorhexidineTitaniumSodium FluorideStainless SteelNickeltitanium nickelidebeta titanium

Autor:innen und Institutionen

  • Department of Orthodontics & Dentofacial Orthopaedics, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
  • Department of Public Health Dentistry, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.

ORCID-Profile: Ritesh Singla, Nishu Singla

Zitieren

APA

Kapur, N., Singla, R., Singla, N., & Natarajan, M. (2025). Evaluation of the effect of two conventional and one herbal mouthwash on the modulus of elasticity of three orthodontic wires: an in vitro study. F1000Research. https://doi.org/10.12688/f1000research.156706.2

Vancouver

Kapur N, Singla R, Singla N, Natarajan M. Evaluation of the effect of two conventional and one herbal mouthwash on the modulus of elasticity of three orthodontic wires: an in vitro study. F1000Research. 2025. doi:10.12688/f1000research.156706.2

BibTeX
@article{Kapur2025,
  author = {Kapur, Neharika and Singla, Ritesh and Singla, Nishu and Natarajan, Madhumitha},
  title = {Evaluation of the effect of two conventional and one herbal mouthwash on the modulus of elasticity of three orthodontic wires: an in vitro study},
  journal = {F1000Research},
  year = {2025},
  doi = {10.12688/f1000research.156706.2}
}
Kostenlos starten →