Assessing the severity of thermal discomfort in a building in the course of hot and humid climate
F1000Research · 2024
DOI: 10.12688/f1000research.154075.2 ↗Kurz gefasst
Fachartikel in der Zeitschrift F1000Research, 2024. Verfasst von Thomas Janvier Matongo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Technologies and Applied Science, The University Institute of Technology, The University of Douala, Douala, Cameroon. Hauptthemen laut MEDLINE: Humidity, Hot Temperature, Climate. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This work is an application of experimental temperature data previously collected in a residential building in Douala, Cameroon, in order to analyze thermal discomfort. The data was collected according to three occupancy scenarios over 12 month period using thermohygrometer sensors. The temperature data are analysed in comparison with the comfortable temperature range from 24°C to 28°C. The degree hour (DH) method was used to assess the severity of thermal discomfort in a hot and humid climate. The results reveal that the open C1, closed C2 and inhabited C3 rooms corresponding to scenarios C1, C2 and C3 respectively, have 7270.6°H, 9063.9°H and 10023°H. The inhabited room C3 has the largest DH and although the room C1 has the smallest DH, the latter largely exceeded the tolerable limit value of 1250°H set by the RE2020 Environmental Regulations. Results from this work can serve in building modelling for researchers and architects to act for the alleviation of thermal discomfort in regions with hot and humid climate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory of Technologies and Applied Science, The University Institute of Technology, The University of Douala, Douala, Cameroon.
- Department of Civil Engineering, Advanced Technical Teachers Training College, University of Douala, Douala, Cameroon.
- Laboratory of Mechanics and Adapted Materials LAMMA, Advanced Technical Teachers Training College, University of Douala, Douala, Cameroon.
- Higher Institute of Transport, Logistics and Commerce, University of Ebolowa, Ambam, Cameroon.
- Laboratory of Transports and Applied Logistics, University Institute of Technology, University of Douala, Douala, Cameroon.
ORCID-Profile: Thomas Janvier Matongo
Zitieren
APA
Matongo, T. J., Ngock, G. R. H., Yamb, E., Mba, L., Diboma, B. S., & Tamba, J. G. (2024). Assessing the severity of thermal discomfort in a building in the course of hot and humid climate. F1000Research. https://doi.org/10.12688/f1000research.154075.2
Vancouver
Matongo TJ, Ngock GRH, Yamb E, Mba L, Diboma BS, Tamba JG. Assessing the severity of thermal discomfort in a building in the course of hot and humid climate. F1000Research. 2024. doi:10.12688/f1000research.154075.2
BibTeX
@article{Matongo2024,
author = {Matongo, Thomas Janvier and Ngock, Gilbert Roméo Hubert and Yamb, Emmanuel and Mba, Léopold and Diboma, Benjamin Salomon and Tamba, Jean Gaston},
title = {Assessing the severity of thermal discomfort in a building in the course of hot and humid climate},
journal = {F1000Research},
year = {2024},
doi = {10.12688/f1000research.154075.2}
}
EUVIMED