A Revolutionary Device for Endovascular Aortic Repair of Abdominal Aortic Aneurysm: A Pilot Study

Taofan Taofan iD, Iwan Dakota iD, Sung Gwon Kang, Suko Adiarto iD, Suci Indriani iD, Ruth Grace Aurora, Rendra Mahardika Putra, Bagas Adhimurda Marsudi, Melani Limenco Benly, Macmilliac Lam iD, Muhammad Rafli Iqbal, Bagus Herlambang und 3 weitere

F1000Research · 2024

DOI: 10.12688/f1000research.152060.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift F1000Research, 2024. Verfasst von Taofan Taofan und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology and Vascular Medicine, Faculty of Medicine University of Indonesia, University of Indonesia Academic Hospital, National Card…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Endovascular Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Endovascular repair for abdominal aortic aneurysms (AAA) has been the gold standard since it was established in 1991. Various graft configurations have been developed to overcome the limitations of endovascular aortic repair (EVAR), including contralateral gate cannulation (CGC). We propose a new device and technique intended to simplify endovascular AAA repair, along with reports of its application in six patients.

Intervention

The Taofan and Kang (T&K) bidirectional endovascular aortic repair (B-EVAR (B-EVAR) device uses a main-body stent graft, two-limb extensions, and bare metal stent. The procedure involved accessing the right and left femoral arteries, followed by standard aortography evaluation using a pigtail catheter through the contralateral femoral access. The main body stent graft is deployed through ipsilateral femoral access using a balloon catheter, while the contralateral gate is cannulated with a hydrophilic coated wire. Both balloons were inflated simultaneously to ensure that the wires were in different lumens. Contralateral and ipsilateral extensions were deployed using a limb extension stent graft. Standard aortography evaluation was repeated.

Result

T&K B-EVAR pilot procedures proved successful in various cases, from simple to complex anatomy, and even with varied graft stent deployment strategies. None of the patients had complications or prolonged length of stay (LOS). Follow-up CT did not reveal any high-pressure endoleaks.

Conclusion

T&K B-EVAR has been proven to simplify endovascular AAA repair in six patients with excellent results. It is also reproducible, potentially universally applicable, and can offer operators ease of use, faster procedure times, reduced fluoroscopy times, and reduced contrast usage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, AbdominalEndovascular ProceduresHumansPilot ProjectsAgedMaleFemaleStentsAged, 80 and overBlood Vessel Prosthesis ImplantationBlood Vessel ProsthesisMiddle AgedEndovascular Aneurysm Repair

Stichwörter der Autor:innen

Abdominal Aortic AneurysmB-EVARContralateral Gate CannulationEndovascular Aortic RepairStent Graft

Autor:innen und Institutionen

  • Department of Cardiology and Vascular Medicine, Faculty of Medicine University of Indonesia, University of Indonesia Academic Hospital, National Cardiovascular Center Harapan Kita, Jakarta, Jakarta, 11420, Indonesia.
  • Department of Radiology, Chosun University, Gwangju-Si, Gwangju-Si, 61452, South Korea.
  • Research Assistant of Vascular Division, Department of Cardiology and Vascular Medicine, Faculty of Medicine University of Indonesia, National Cardiovascular Center Harapan Kita, Jakarta, Jakarta, 11420, Indonesia.
  • Department of Thorax and Cardiovascular Surgeon, Faculty of Medicine University of Indonesia, University of Indonesia Academic Hospital, National Cardiovascular Center Harapan Kita, Jakarta, Jakarta, 11420, Indonesia.

ORCID-Profile: Taofan Taofan, Iwan Dakota, Suko Adiarto, Suci Indriani, Macmilliac Lam

Zitieren

APA

Taofan, T., Dakota, I., Kang, S. G., Adiarto, S., Indriani, S., Aurora, R. G., Putra, R. M., Marsudi, B. A., Benly, M. L., Lam, M., Iqbal, M. R., Herlambang, B., Yuniadi, Y., Sukmawan, R., & Widyantoro, B. (2024). A Revolutionary Device for Endovascular Aortic Repair of Abdominal Aortic Aneurysm: A Pilot Study. F1000Research. https://doi.org/10.12688/f1000research.152060.2

Vancouver

Taofan T, Dakota I, Kang SG, Adiarto S, Indriani S, Aurora RG, et al. A Revolutionary Device for Endovascular Aortic Repair of Abdominal Aortic Aneurysm: A Pilot Study. F1000Research. 2024. doi:10.12688/f1000research.152060.2

BibTeX
@article{Taofan2024,
  author = {Taofan, Taofan and Dakota, Iwan and Kang, Sung Gwon and Adiarto, Suko and Indriani, Suci and Aurora, Ruth Grace and Putra, Rendra Mahardika and Marsudi, Bagas Adhimurda and Benly, Melani Limenco and Lam, Macmilliac and Iqbal, Muhammad Rafli and Herlambang, Bagus and Yuniadi, Yoga and Sukmawan, Renan and Widyantoro, Bambang},
  title = {A Revolutionary Device for Endovascular Aortic Repair of Abdominal Aortic Aneurysm: A Pilot Study},
  journal = {F1000Research},
  year = {2024},
  doi = {10.12688/f1000research.152060.2}
}
Kostenlos starten →