EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Hemodynamic Validation of Automated Segmentation for Patient-Specific Aortic CFD in Severe Aortic Valve Stenosis

Michael Chmalantze, Anastasios Raptis, Christos Manopoulos

Technical Annals · 28.04.2026 · 2 (4)

DOI: 10.12681/ta.46947 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technical Annals, online erschienen am 28.04.2026. Verfasst von Michael Chmalantze und 2 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Severe aortic valve stenosis (AS) obstructs blood flow across the aortic valve, generating high-velocity jets and elevated pressures that place abnormal mechani-cal loading on the ascending aorta. Patient-specific computational fluid dynamics (CFD) is a valuable tool for characterizing these hemodynamic disturbances, but its clinical adoption is limited by the time required to manually reconstruct patient geometries from computed tomography angiography (CTA) images. This study evaluates whether an automated segmentation workflow can reproduce the hemo-dynamic accuracy of manual reconstruction for patient-specific aortic CFD. Three-dimensional aortic models for four patients with severe AS, previously generated via both automated (Auto) and manual (Manual) segmentation of CTA images, were used, yielding eight geometries in total. Simulations were per-formed in SimVascular using a customized parabolic inlet velocity profile repre-senting a 65% stenotic area reduction, together with a three-element RCR Wind-kessel model at the outlets, a rigid arterial wall, and a Newtonian blood model. The simulated inlet pressure waveform (systolic/diastolic peaks of approximately 130/60 mmHg) closely matched values reported in the literature for severe AS patients. Across all four patient cases, the Auto and Manual models produced pressure and time-averaged wall shear stress (TAWSS) distributions in close agreement, with elevated hemodynamic loading consistently located at the same anatomical sites. These results indicate that automated segmentation can generate geometries suitable for patient-specific aortic CFD while substantially reducing model preparation time, supporting its use as a scalable alternative to manual reconstruction.

Zitieren

APA

Chmalantze, M., Raptis, A., & Manopoulos, C. (2026). Hemodynamic Validation of Automated Segmentation for Patient-Specific Aortic CFD in Severe Aortic Valve Stenosis. Technical Annals, 2(4). https://doi.org/10.12681/ta.46947

Vancouver

Chmalantze M, Raptis A, Manopoulos C. Hemodynamic Validation of Automated Segmentation for Patient-Specific Aortic CFD in Severe Aortic Valve Stenosis. Technical Annals. 2026;2(4). doi:10.12681/ta.46947

BibTeX
@article{Chmalantze2026,
  author = {Chmalantze, Michael and Raptis, Anastasios and Manopoulos, Christos},
  title = {Hemodynamic Validation of Automated Segmentation for Patient-Specific Aortic CFD in Severe Aortic Valve Stenosis},
  journal = {Technical Annals},
  year = {2026},
  volume = {2},
  number = {4},
  doi = {10.12681/ta.46947}
}
Kostenlos starten →