EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Computational simulation of coracoclavicular screw insertion through the superior distal clavicular plate for clinical applications in Korean cadavers

Hyung-Lae Cho, Ji Han Choi, Se-Lin Jeong, Gu-Hee Jung

Journal of Musculoskeletal Trauma · 2025

DOI: 10.12671/jmt.2025.00122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Musculoskeletal Trauma, 2025. Verfasst von Hyung-Lae Cho und 3 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Gyeongsang National University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The study was conducted to determine the practical area for inserting the coracoclavicular (CC) screw through the plate by analyzing three-dimensional (3D) shoulder models featuring virtually implanted, actual-size plates and screws.

Methods

Ninety cadaveric shoulders (41 males and 49 females) underwent continuous 1.0-mm slice computed tomography scans. The data were imported into image-processing software to generate a 3D shoulder model, including the scapula and clavicle. The overlapping area between the clavicle and the horizontal portion of the coracoid process (horizontal portion_CP) was analyzed in the cranial view. A curved pelvic recon plate was virtually placed on the upper surface of the distal clavicle, and an actual-size (3.5 mm) CC screw was inserted through the plate.

Results

The distal clavicle directly overlapped with the horizontal portion_CP in the vertical direction. The overlapping area was sufficient to place the 3.5 mm and 4.5 mm-sized screws. In all shoulder models, the CC screw could be inserted through the plate into the vertical direction, with an average length of 35.5 mm (range, 26.2–62.5 mm; standard deviation, 1.2 mm). In 87 models, the CC screw was inserted through the third hole from the lateral end of the plate. Two models were inserted through the second hole, and one model through the fourth hole.

Conclusions

The upper surface of the clavicle has sufficient overlapping area to place CC screws through the plate in the vertical direction in the corresponding hole. Supplemental CC screw fixation through the plate can be performed without additional or special equipment.Level of evidence: IV

Förderung

  • Gyeongsang National University

Zitieren

APA

Cho, H., Choi, J. H., Jeong, S., & Jung, G. (2025). Computational simulation of coracoclavicular screw insertion through the superior distal clavicular plate for clinical applications in Korean cadavers. Journal of Musculoskeletal Trauma. https://doi.org/10.12671/jmt.2025.00122

Vancouver

Cho H, Choi JH, Jeong S, Jung G. Computational simulation of coracoclavicular screw insertion through the superior distal clavicular plate for clinical applications in Korean cadavers. Journal of Musculoskeletal Trauma. 2025. doi:10.12671/jmt.2025.00122

BibTeX
@article{Cho2025,
  author = {Cho, Hyung-Lae and Choi, Ji Han and Jeong, Se-Lin and Jung, Gu-Hee},
  title = {Computational simulation of coracoclavicular screw insertion through the superior distal clavicular plate for clinical applications in Korean cadavers},
  journal = {Journal of Musculoskeletal Trauma},
  year = {2025},
  doi = {10.12671/jmt.2025.00122}
}
Kostenlos starten →