EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Outcomes of open reduction and internal fixation using 2.0/2.4 mm locking compression plate in isolated greater tuberosity fractures of humerus

Sung Choi, Dongju Shin, Sangwoo Kim, Byung Hoon Kwack

Journal of Musculoskeletal Trauma · 2025

DOI: 10.12671/jmt.2025.00005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Musculoskeletal Trauma, 2025. Verfasst von Sung Choi und 3 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The purpose of this study was to retrospectively evaluate the radiographic and clinical results of a small single or double low-profile plate fixation of 2.0/2.4 mm locking compression plate (LCP) in treating isolated greater tuberosity (GT) fractures of the humerus.

Methods

From June 2015 to October 2022, patients who underwent LCP in treating isolated GT fractures of the humerus were included in this study. The radiological and clinical results were analyzed in 15 patients who underwent open reduction and internal fixation used 2.0/2.4 mm LCP.

Results

Bone union was achieved in 14 patients (93.3%) and one failed case was treated with a 2.4 mm single LCP fixation. Radiological union was achieved within 10–20 weeks. Complications occurred in two patients (13.3%), including the reduction failure and shoulder stiffness. At the final follow-up, the average clinical scores were as follows: a visual analog scale for pain of 2.1 (range, 0–5) and a University of California, Los Angeles score of 27.2 (range, 18–31). Regarding range of motion (ROM), the average active ROMs were 142° for forward flexion (range, 120°–150°), 147.1° for abduction (range, 120°– 180°), and 59.3° for external rotation (range, 45°–80°). For internal rotation, the average was observed to reach the 10th thoracic vertebra (range, 1st lumbar vertebra–7th thoracic vertebra).

Conclusions

The clinical and radiologic outcomes of treating isolated GT fracture using 2.0/2.4 mm LCP were favorable, and double low-profile plate fixation may be beneficial for sufficient fracture stability if possible. Level of evidence: Level IV, case series.

Zitieren

APA

Choi, S., Shin, D., Kim, S., & Kwack, B. H. (2025). Outcomes of open reduction and internal fixation using 2.0/2.4 mm locking compression plate in isolated greater tuberosity fractures of humerus. Journal of Musculoskeletal Trauma. https://doi.org/10.12671/jmt.2025.00005

Vancouver

Choi S, Shin D, Kim S, Kwack BH. Outcomes of open reduction and internal fixation using 2.0/2.4 mm locking compression plate in isolated greater tuberosity fractures of humerus. Journal of Musculoskeletal Trauma. 2025. doi:10.12671/jmt.2025.00005

BibTeX
@article{Choi2025,
  author = {Choi, Sung and Shin, Dongju and Kim, Sangwoo and Kwack, Byung Hoon},
  title = {Outcomes of open reduction and internal fixation using 2.0/2.4 mm locking compression plate in isolated greater tuberosity fractures of humerus},
  journal = {Journal of Musculoskeletal Trauma},
  year = {2025},
  doi = {10.12671/jmt.2025.00005}
}
Kostenlos starten →