EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

The clinical outcome of treating elderly distal radius fractures by long volar locking plate with the elimination of irreducible metaphyseal comminuted volar cortical fragments: a retrospective case series

Soo Min Cha

Journal of Musculoskeletal Trauma · 2025

DOI: 10.12671/jmt.2025.00003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Musculoskeletal Trauma, 2025. Verfasst von Soo Min Cha. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Chungnam National University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In severe comminuted metaphyseal distal radius fracture (DRF) of elderly patients, after maintaining only radiological parameters of the radius using long volar locking plates (VLPs), we inevitably eliminated a few volar cortical fragments of metaphysis. Here, we report the final radiological and clinical outcomes of our method.

Methods

For the patients who were treated between 2014 and 2018, the demographic factors, the preoperative radiologic factors, area of the eliminated volar cortical fragment, and final radiologic parameter, were evaluated. Clinical outcomes and ranges of active motion were evaluated.

Results

In total, 31 patients were included. The mean patient age was 77.3 years and the mean eliminated cortical area was 3.30 cm2. At the final follow-up, the mean volar tilt, radial inclination, articular step-off, and ulnar variance were 10.35°, 20.00°, 0.58 mm, and 0.71 mm, respectively. There were no definitive correlations between bone mineral density, fragment area, the largest cortical fragment diameter ratio and differences in final and immediate postoperative measurements of these radiological parameters, respectively. Visual analog scale and disabilities of the arm, shoulder, and hand (DASH) scores were satisfactory, and the mean arcs of flexion-extension and pronation-supination were 124.35° and 133.23°. Clinical outcomes were not significantly different according to the AO system category.

Conclusions

For maintenance of radiological parameters of the radius, long VLPs are useful in older patients with DRFs who exhibit volar metaphyseal comminution, despite concurrent ulnar fractures. Inevitable elimination of irreducible free comminuted cortical fragments when filling the defect does not affect final radiological and clinical outcomes. Level of evidence: Level IV, case series.

Förderung

  • Chungnam National University

Zitieren

APA

Cha, S. M. (2025). The clinical outcome of treating elderly distal radius fractures by long volar locking plate with the elimination of irreducible metaphyseal comminuted volar cortical fragments: a retrospective case series. Journal of Musculoskeletal Trauma. https://doi.org/10.12671/jmt.2025.00003

Vancouver

Cha SM. The clinical outcome of treating elderly distal radius fractures by long volar locking plate with the elimination of irreducible metaphyseal comminuted volar cortical fragments: a retrospective case series. Journal of Musculoskeletal Trauma. 2025. doi:10.12671/jmt.2025.00003

BibTeX
@article{Cha2025,
  author = {Cha, Soo Min},
  title = {The clinical outcome of treating elderly distal radius fractures by long volar locking plate with the elimination of irreducible metaphyseal comminuted volar cortical fragments: a retrospective case series},
  journal = {Journal of Musculoskeletal Trauma},
  year = {2025},
  doi = {10.12671/jmt.2025.00003}
}
Kostenlos starten →