Analysis of platelet rich plasma preparations by routine centrifuge versus two commercially available standardized centrifuges
Pakistan Journal of Medical Sciences · 28.07.2026 · 42 (8) · 2006-2013
DOI: 10.12669/pjms.42.8.15762 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pakistan Journal of Medical Sciences, online erschienen am 28.07.2026. Verfasst von Syed Kamran Ahmed und 2 weiteren Autor:innen. Beteiligte Einrichtung: Syed Kamran Ahmed, FCPS Department of Orthopaedics & Traumatology, Indus Hospital & Health Network, Karachi, Pakistan. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background & Objective: Platelet-rich plasma (PRP) therapy is increasingly used in regenerative medicine, orthopedics, and dermatology; however, the lack of standardization in PRP preparation leads to variability in platelet yield and composition. This study aimed to compare the quality and efficiency of PRP prepared using a routine laboratory centrifuge with two commercially available standardized centrifuge systems. Methodology: This comparative cross-sectional study was conducted in the Department of Orthopedics & Traumatology and the Department of Plastic surgery at Indus Hospital & Health Network (IHHN), Karachi, over a period of six months from August, 2025 to January 2026. Non-probability consecutive sampling was employed. Thirty-six PRP samples were prepared using routine single-spin, routine double-spin, and two commercial centrifugation methods. Platelet and leukocyte counts, hemoglobin contamination, and platelet recovery were analyzed using SPSS version 26.
Results
Commercial standardized centrifuge systems yielded significantly higher platelet concentrations (mean 835 ± 120 ×10⁹/L) compared to routine centrifuges (mean 25.5 ± 10.9 ×10⁹/L; p = 0.005). Platelet recovery and fold increase were also superior in commercial systems (mean 81.6% ± 5.94 vs. mean 10.65% ± 4.59). Leukocyte count and hemoglobin contamination were relatively lower in routine centrifuge methods compared to commercial PRP therapy. Among routine protocols, both single-spin and double-spin methods produced poor platelet counts when the entire supernatant fluid was examined as in our study.
Conclusion
Commercial standardized centrifuges produce PRP with reliable and greater platelet enrichment. Routine centrifuge, on the other hand, consistently produced poor platelet counts in the entire supernatant fluid and hence the lower one third only should be used preferably by double spin method. Different spin protocols and collection methods need to be evaluated to better document platelet enhancement in routine centrifuge use.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Syed Kamran Ahmed, FCPS Department of Orthopaedics & Traumatology, Indus Hospital & Health Network, Karachi, Pakistan.
- Asifa Abdul Hakeem, FCPS Department of Orthopaedics & Traumatology, Indus Hospital & Health Network, Karachi, Pakistan.
- Sadaf Saeed, FCPS Plastic surgery Department of Plastic Surgery, Indus Hospital & Health Network, Karachi, Pakistan.
Zitieren
APA
Ahmed, S. K., Hakeem, A. A., & Saeed, S. (2026). Analysis of platelet rich plasma preparations by routine centrifuge versus two commercially available standardized centrifuges. Pakistan Journal of Medical Sciences, 42(8), 2006-2013. https://doi.org/10.12669/pjms.42.8.15762
Vancouver
Ahmed SK, Hakeem AA, Saeed S. Analysis of platelet rich plasma preparations by routine centrifuge versus two commercially available standardized centrifuges. Pakistan Journal of Medical Sciences. 2026;42(8):2006-2013. doi:10.12669/pjms.42.8.15762
BibTeX
@article{Ahmed2026,
author = {Ahmed, Syed Kamran and Hakeem, Asifa Abdul and Saeed, Sadaf},
title = {Analysis of platelet rich plasma preparations by routine centrifuge versus two commercially available standardized centrifuges},
journal = {Pakistan Journal of Medical Sciences},
year = {2026},
volume = {42},
number = {8},
pages = {2006--2013},
doi = {10.12669/pjms.42.8.15762}
}
EUVIMED