EUVIMEDEUVIMED entdecken
Open Access

Evaluation of the Caval-Aortic Index During Early Fluid Resuscitation in Patients With Acute Pancreatitis

Tuba Şafak, Ahmet Burak Erdem iD, Nur Vahapoğlu Vural, Emre Çakar

Medical Science Monitor · 2026

DOI: 10.12659/msm.954804 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Science Monitor, 2026. Verfasst von Tuba Şafak und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Ankara Etlik City Hospital, Ankara, Turkey. Hauptthemen laut MEDLINE: Pancreatitis, Fluid Therapy, Vena Cava, Inferior, Aorta. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Early fluid resuscitation is a cornerstone of acute pancreatitis management; however, bedside assessment of the early hemodynamic response remains challenging. We prospectively evaluated serial ultrasonographic parameters and peripheral venous pressure (PVP) during initial fluid resuscitation in patients with acute pancreatitis. MATERIAL AND METHODS Patients with confirmed acute pancreatitis underwent serial measurements of inferior vena cava (IVC) diameter, aortic diameter, caval-aortic (IVC/Ao) index, PVP, and mean arterial pressure (MAP) before and 2 hours after fluid resuscitation. Early hemodynamic response was defined as an increase of at least 10% in MAP from baseline. Correlation and receiver operating characteristic (ROC) analyses with DeLong's test were performed. RESULTS Sixty patients were included. After fluid resuscitation, IVC diameter, IVC/Ao index, PVP, and MAP significantly increased, whereas aortic diameter remained unchanged. Changes in IVC diameter (ΔIVC) were positively correlated with changes in MAP (ΔMAP); changes in aortic diameter (ΔAorta) showed a significant inverse correlation. The ΔIVC/Ao index showed a similar positive trend, but this correlation was not statistically significant. ΔAorta demonstrated the highest discriminatory performance for identifying MAP-defined early hemodynamic response (area under the curve, 0.680; 95% confidence interval, 0.535-0.824), although pairwise ROC analysis revealed no significant superiority over the other ultrasonographic parameters. CONCLUSIONS Serial ultrasonographic assessment may provide clinically relevant information during early fluid resuscitation in acute pancreatitis. No ultrasonographic parameter demonstrated clear superiority. ΔAorta showed the numerically highest, although modest, discriminatory performance in this cohort. These findings should be considered hypothesis-generating and warrant further investigation before any comparative advantage of arterial ultrasonographic assessment can be inferred.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PancreatitisFluid TherapyVena Cava, InferiorAortaHumansFemaleMaleMiddle AgedHemodynamicsUltrasonographyAdultProspective StudiesResuscitationROC CurveAcute DiseaseAgedArterial Pressure

Autor:innen und Institutionen

  • Department of Emergency Medicine, Ankara Etlik City Hospital, Ankara, Turkey.

ORCID-Profile: Ahmet Burak Erdem

Zitieren

APA

Şafak, T., Erdem, A. B., Vural, N. V., & Çakar, E. (2026). Evaluation of the Caval-Aortic Index During Early Fluid Resuscitation in Patients With Acute Pancreatitis. Medical Science Monitor. https://doi.org/10.12659/msm.954804

Vancouver

Şafak T, Erdem AB, Vural NV, Çakar E. Evaluation of the Caval-Aortic Index During Early Fluid Resuscitation in Patients With Acute Pancreatitis. Medical Science Monitor. 2026. doi:10.12659/msm.954804

BibTeX
@article{afak2026,
  author = {Şafak, Tuba and Erdem, Ahmet Burak and Vural, Nur Vahapoğlu and Çakar, Emre},
  title = {Evaluation of the Caval-Aortic Index During Early Fluid Resuscitation in Patients With Acute Pancreatitis},
  journal = {Medical Science Monitor},
  year = {2026},
  doi = {10.12659/msm.954804}
}
Kostenlos starten →