Comparative Spectrophotometric Assessment of Crown Discoloration from Diverse Endodontic Sealers
Medical Science Monitor · 2025
DOI: 10.12659/msm.947874 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Medical Science Monitor, 2025. Verfasst von Adel S Alobaid und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia. Hauptthemen laut MEDLINE: Root Canal Filling Materials, Tooth Discoloration, Tooth Crown. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND Crown discoloration is a significant aesthetic concern in endodontics, particularly following the use of obturation sealers. Using spectrophotometric analysis, this study evaluated the extent of discoloration caused by 4 types of sealers: mineral trioxide aggregate (MTA)-based, zinc oxide eugenol (ZnOE)-based, calcium hydroxide (Ca(OH)2)-based, and resin-based sealers. MATERIAL AND METHODS We randomly divided 75 extracted maxillary central incisors into 5 groups: 4 experimental groups and 1 control group. Standardized endodontic treatment was performed, with the respective sealers placed according to the manufacturer's instructions. Coronal discoloration was measured using a spectrophotometer at baseline, immediately after treatment, and at 1 and 6 months. Chromatic parameters (CIE L*, a*, b*) and total color difference (ΔE) were analyzed. Statistical analysis included repeated-measures ANOVA and post hoc tests. RESULTS All sealers caused significant crown discoloration over time. The MTA-based sealer exhibited the least discoloration, while ZnOE-based sealers had the highest ΔE values. Significant changes were noted in chromatic parameters across materials and time. ΔL (lightness change) ranged from 1.53±1.67 for MTA to 4.06±1.96 for Resin-based sealers at baseline to immediately after treatment. Resin-based sealers had the highest mean change (2.18±2.40) in Δb. For ΔE, significant differences were found between materials, with Ca(OH)₂ showing the highest mean change (5.04±2.59). CONCLUSIONS Endodontic sealers can induce varying degrees of crown discoloration, with ZnOE-based sealer causing the most significant changes. Clinicians should consider the aesthetic impact of sealer selection, particularly for anterior teeth.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Endodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Aabha, Saudi Arabia.
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
- Department of Dental Education, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
- Department of Prosthodontics, Sharad Pawar Dental College, DMIHER, Wardha, Maharashtra, India.
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
ORCID-Profile: Mohammed A Alobaid, Saurabh Chaturvedi
Zitieren
APA
Alobaid, A. S., Mkhreb, S. S., Ali, A. B. M., Alobaid, M. A., Dubey, S. A., Elmahdi, A. E., & Chaturvedi, S. (2025). Comparative Spectrophotometric Assessment of Crown Discoloration from Diverse Endodontic Sealers. Medical Science Monitor. https://doi.org/10.12659/msm.947874
Vancouver
Alobaid AS, Mkhreb SS, Ali ABM, Alobaid MA, Dubey SA, Elmahdi AE, et al. Comparative Spectrophotometric Assessment of Crown Discoloration from Diverse Endodontic Sealers. Medical Science Monitor. 2025. doi:10.12659/msm.947874
BibTeX
@article{Alobaid2025,
author = {Alobaid, Adel S and Mkhreb, Shahrah S and Ali, Ahmed Babiker Mohamed and Alobaid, Mohammed A and Dubey, Surekha Anil and Elmahdi, Asim Elsir and Chaturvedi, Saurabh},
title = {Comparative Spectrophotometric Assessment of Crown Discoloration from Diverse Endodontic Sealers},
journal = {Medical Science Monitor},
year = {2025},
doi = {10.12659/msm.947874}
}
EUVIMED